5. Turn ON the machine, completely lower the scrub
head to the fl oor, turn OFF the machine, and
remove the key.
6. Disconnect the battery cable from the machine.
FOR SAFETY: When servicing machine, Disconnect
battery connection and charger cord before
working on machine.
7. Remove the front scrub head cover from the
machine.
8. Cut the cable ties from the main wire harness /
brush motor connection and disconnect the main
wire harness from the brush motors.
9. Disconnect all solution supply hoses from the scrub
head.
10. Cut all wire ties securing the main wire harness to
the scrub head and disconnect main wire harness
connections from the brush drive motors.
11. Remove the cotter pin and clevis pin securing the
actuator to the head suspension spring bracket.
12. Remove the cotter pins and clevis pins securing
the head lift arms to the scrub head assembly.
13. Remove the clevis pin and cotter pin securing the
scrub head pivot to the head guide bracket.
14. Reinstall the removed scrub head / install the new
scrub head onto the machine in the reverse order
of removal.
15. If removed scrub head was replaced with new
orbital scrub head, reconfi gure the machine for the
orbital scrub head. See RECONFIGURING THE
MACHINE AFTER NEW HARDWARE / OPTION
INSTALLATION in this section of the manual.
Summary of Contents for t500
Page 5: ...5 T500 9015504 01 2018 CONTENTS ...
Page 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Page 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Page 111: ...111 T500 9015504 01 2018 SERVICE ...
Page 117: ...117 T500 9015504 01 2018 SERVICE ...
Page 146: ...146 T500 9015504 01 2018 SERVICE ...