TROUBLESHOOTING
MACHINE FAILED TO PROPEL
Step
Action
Value(s)
Yes
No
1
• Key ON
• Enable propel
• Is there a fl ashing BDI fault or LCD Pro-Panel (option)
fault code present?
See FAULTS
in TROUBLE-
SHOOTING sec-
tion of this manual
Proceed to
STEP 2
2
• Key OFF
• Firmly press circuit breaker #4 to reset
• Is circuit breaker #4 tripped?
Reset and test
power-up circuit
operation
Proceed to
STEP 3
3
• See SERVICE DIAGNOSTICS TOOL in SERVICE section
of this manual and confi rm software is properly confi gured
to enable propel
• Is software confi gured properly?
Proceed to
STEP 4
Reprogram
software
4
• Key OFF
• Place machine on blocks so drive wheels are lifted from
fl oor
• Key ON
• Enable propel
• Test voltage applied to propel subsystem as shown on
electrical schematic
• Are electrical circuits operating as shown on electrical
schematic?
Repeat STEP 1
Identify voltage
drop location
and repair or
replace neces-
sary compo-
nents
Terms:
BDI = Battery Discharge Indicator