![Tennant t500 Service Information Manual Download Page 66](http://html1.mh-extra.com/html/tennant/t500/t500_service-information-manual_1087311066.webp)
66
T500 9015504 01-2018
TROUBLESHOOTING
SCRUB HEAD LIFT ACTUATOR
28/GRY
MTR
Lift Actuator
(3-5 Amps)
NOTE:
Orbital head lift actuator adjusts to one of three
pre-set internal switch conditions based on the
down pressure selection made on the touch panel.
• Extend limit Sw. open = minimum DP.
• Middle Sw. closed = medium DP.
• Retract limit Sw. open = maximum DP.
Cylindrical and dual disk heads adjust actuator
to scrub motors current based on down pressure selection.
MACHINE CONTROL
MODULE
B+
KSI
(KEY SWITCH INTERLOCK)
ACT_A
ACT_B
DIGITAL_GND1
GND_1
DIGITAL_GND3
1/RED
46/BL
U
46/BLU
BLU
J5
J7-1
J7-3
J7-4
J12-8
J7-8
J6-10
13/BLK
INPUT 4
(CLOSED = HEAD DOWN)
J6-5
B-
J1
BLK
13/BLK
13/BLK
13/BLK
1
2
B
A
19/WHT
EXTEND
LIMIT SW.
MIDDLE
POSITION SW.
RETRACT
LIMIT SW.
43/ORG
MIDDLE POSITION INPUT
(CLOSED = DP Level 2)
28/GRY
J6-5
FU1
100A
Lift
Actuator
(Option)
Enabled
•
Head Lowered -
One Step Button
Disabled
Operational Matrix:
• Head Raised - One Step Button
• Low Battery Voltage
• Load Current Fault
• Battery Charger ON Interlock
Battery Po
Battery Negative -
Unswit
ched B+
Batt
er
y (-)
Gr
ound
Switched B+Aux Contactor
Relay
Summary of Contents for t500
Page 5: ...5 T500 9015504 01 2018 CONTENTS ...
Page 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Page 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Page 111: ...111 T500 9015504 01 2018 SERVICE ...
Page 117: ...117 T500 9015504 01 2018 SERVICE ...
Page 146: ...146 T500 9015504 01 2018 SERVICE ...