54
T500 9015504 01-2018
TROUBLESHOOTING
OFF-BOARD CHARGER ERROR AND FAULT
CODES
Code
Description
Cause
Solution
E-0-0-1
E-0-2-1
Battery high voltage
1. Wrong battery voltage for charger.
2. Other charger also attached.
3. Resistive battery.
Check battery voltage and cable con-
nections. Check battery size and condi-
tion. Error will automatically clear once
voltage is in range.
E-0-0-2
E-0-2-2
Battery low voltage
1. Battery disconnected.
2. Battery over discharged.
Check battery voltage and cable con-
nections. Check battery size and condi-
tion. Error will automatically clear once
voltage is in range.
E-0-0-3
Charge time out caused by bat-
tery pack not reaching required
voltage within safe time limit.
(charge profi le dependent)
1. Charger output reduced due to
high temperatures.
2. Poor battery health.
3. Very deeply discharged battery.
4. Poorly connected battery.
Operate at lower ambient temperature.
Replace battery pack. Check DC con-
nections. Error will clear once charger is
reset by cycling DC or AC.
E-0-0-4
Battery could not meet minimum
voltage (charge profi le depen-
dent)
1. Shorted or damaged cells.
Replace battery pack. Check DC con-
nections. Error will automatically clear
once charger is reset by cycling DC or
AC.
E-0-0-7
Battery amp hour limit exceeded
1. Poor battery health.
2. Very deeply discharged battery.
3. Poorly connected battery.
4. High parasitic loads on battery
while charging
Replace battery pack. Check DC con-
nections. Disconnect parasitic loads. Er-
ror will automatically clear once charger
is reset by cycling DC or AC.
E-0-0-8
Battery temperature is out of
range
1. Possible battery temperature sen-
sor error.
Check temperature sensor and con-
nections. Reset charger. Error will clear
once condition has been corrected.
E-0-1-2
Reverse polarity error
1. Battery incorrectly connected to
charger.
Check battery connections. Error will
clear once condition has been corrected
E-0-1-6
E-0-1-8
E-0-2-6
USB operation failed (software)
1. Software upgrade failure.
2. Script operation failure.
Ensure USB fl ash drive is properly for-
matted and reinsert USB fl ash drive.
E-0-1-7
USB operation failed (hardware)
1. Hardware upgrade failure.
Remove and reinsert USB drive. If
condition persists, cycle AC and retry by
reinserting USB drive.
E-0-2-3
High AC voltage error
(>270VAC)
1. Voltage error.
Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz. Error will clear once
condition has been corrected.
E-0-2-4
Charger failed to initialize
1. Charger has failed to turn on
properly
Disconnect AC input and battery for 30
seconds before retrying.
E-0-2-5
Low AC voltage oscillation error
1. AC source is unstable.
2. Undersized generator.
3. Severely undersized input cables
Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz. Error will clear once
condition has been corrected.
F-0-0-1
F-0-0-2
F-0-0-3
F-0-0-4
F-0-0-6
Internal charger fault
1. Internal charger fault.
Remove AC and battery for minimum
30 seconds and retry charger. If it fails
again, contact the vehicle or machine
manufacturer.
Off-Board Charger Error and Fault Codes table taken
from the Delta-Q IC650 Charger Manual.
© Delta-Q Technologies Corp. (PN: 710-0138 Rev 3
Date: 14/07/2014)
Summary of Contents for t500
Page 5: ...5 T500 9015504 01 2018 CONTENTS ...
Page 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Page 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Page 111: ...111 T500 9015504 01 2018 SERVICE ...
Page 117: ...117 T500 9015504 01 2018 SERVICE ...
Page 146: ...146 T500 9015504 01 2018 SERVICE ...