MAINTENANCE
CHANGING ON-BOARD BATTERY CHARGER
SETTINGS (Pro-Membrane model)
To manually change the on-board battery charger
settings for a different battery type, carefully follow
instructions as described below
NOTE: The manual method is only an alternative
if unable to change setting by use of the Service
Application Software performed by Service.
1. Disconnect the battery cable connection at
machine.
FOR SAFETY: When servicing machine, stop on
level surface, turn off machine, remove key, and set
parking brake if equipped.
2. Unwrap the battery charger power cord from the
cord hooks.
3. Using a T25 star screwdriver, remove the two
screws located at the bottom of the control console
to access battery charger.
4. Carefully peel back the charger display label to
access the dial settings.
5. Using a small standard screwdriver, turn the dial
to the appropriate battery type according to the
following chart.
Dial
Position
Battery Description Settings
with AH Ranges
0
CAN-BUS setting*
1
Wet, Trojan 180-260 AH
2
Wet, Trojan 270-360 AH
3
Wet, Enersys/Tab 200-350 AH
4
AGM, Tianneng 180-260 AH
5
AGM, Discover 200-350 AH
6
Gel, Sonnenschein 80-150 AH
* The CAN-BUS setting, dial position “0”, is the
software setting that is programmed to match battery
type supplied with machine. When the dial is manually
changed to a different setting, it should not be reset
back to “0” otherwise battery damage may result.
Service Application Software is required to reset dial
back to “0”. Contact Service.
6. Re-apply the display label.
7. Replace the control console.
8. To set the BDI for the new battery type, plug the
on-board battery charger cord into an electrical
outlet. The machine’s software will automatically
reprogram the BDI to the new battery type.
Summary of Contents for t500
Page 5: ...5 T500 9015504 01 2018 CONTENTS ...
Page 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Page 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Page 111: ...111 T500 9015504 01 2018 SERVICE ...
Page 117: ...117 T500 9015504 01 2018 SERVICE ...
Page 146: ...146 T500 9015504 01 2018 SERVICE ...