![Tennant M17 Series Service Information Manual Download Page 220](http://html1.mh-extra.com/html/tennant/m17-series/m17-series_service-information-manual_1086877220.webp)
5-3
8
SERVICE
TESTINg PROPEL mOTOR CaBLES
BET009
2 . disconnect u, v, and W cables from W1, a-, and a+
terminals (respectively) .
PMT002
W
U
V
PMT006
U
V
W
12
35
23
1
24
13
3 . disconnect u, v, and W cables from curtis 1232
controller as shown below .
4 . reconnect battery connection and test each cable
using an ohmmeter for a short to b as shown
below . each cable should test as “o .L .” or open to
b . replace shorted cable(s) .
PMT007
W
U
V
Ω
W
U
V
Ω
W
U
V
Ω
1.
2.
3.
3.
U
V
W
+
-
+
-
+
-
+
-
+
-
+
-
6 Volt
6 Volt
6 Volt
6 Volt
6 Volt
6 Volt
FOR SAFETY: Before leaving or servicing machine,
empty solution and recovery tanks, stop on level
surface, set parking brake, turn off machine and
remove key.
FOR SAFETY: When servicing machine, disconnect bat-
tery connection before working on machine.
1 . key off . disconnect batteries . remove terminal box
cover screws and set cover aside.
M
17 Service Information 90
17358
(
08
-
20
1
6
)
Summary of Contents for M17 Series
Page 10: ...1 6 M17 Service Information 9017358 08 2016 SAFETY PRECAUTIONS ...
Page 124: ...4 28 TROUBLESHOOTING M17 Service Information 9017358 08 2016 ...
Page 182: ...4 86 M17 Service Information 9017358 08 2016 TROUBLESHOOTING ...
Page 202: ...5 20 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 203: ...5 21 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 204: ...5 22 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...