TROUBLESHOOTING
STEP
ACTION
VALUE(S)
YES
NO
1
•
Key On
•
Enable main sweep brushes
•
Is there a pertinent fault message
displayed?
See
“
Fault Section"
Go to Step #2
2
•
Key Off
•
See “Manual Mode” section of this manual
•
Activate the sweep brush in manual
mode
•
Does the sweep actuator lower?
Go to Step #
6
Go to Step #3
3
•
Key Off
•
See “Self-Test Mode”
•
Does the Self-Test display output circuits J4-16,17
as open or shorted?
Correct Open
or Short Cir-
cuit Condition
Go to Step #4
4
•
Key O
ff
•
Test voltage applied to actuator as shown on the
electrical schematic
•
Are the electrical circuits operating as shown on the
electrical schematic?
Terms:
J4-16,17= Main Sweep Module
Middle Sweep Up/Down,
Actuator
Go to Step #5
Correct Faulty
Input Condi-
tion
5
•
Key O
ff
•
See TESTING
MAIN
SWEEP
ACTUATOR
in the SER
VICE
s
ection of this manual
•
Does the
actuator m
otor pass the testing?
See TESTING
MAIN SWEEP
ACTUATOR
Go to Step #6
Replace
Actuator
6
•
Key O
ff
•
Reconnect
sweep actuator
to main wire harness
•
Test voltage applied to
actuator
subsystem as
shown on the electrical schematic
•
Are the electrical circuits operating as shown on the
electrical schematic?
Go Back to
Step #1
Identify Volt-
age Drop
Location and
Repair or Re-
place Neces-
sary Compo-
nents
Summary of Contents for M17 Series
Page 10: ...1 6 M17 Service Information 9017358 08 2016 SAFETY PRECAUTIONS ...
Page 124: ...4 28 TROUBLESHOOTING M17 Service Information 9017358 08 2016 ...
Page 182: ...4 86 M17 Service Information 9017358 08 2016 TROUBLESHOOTING ...
Page 202: ...5 20 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 203: ...5 21 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 204: ...5 22 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...