TROUBLESHOOTING
Machine Failed to Power Up
STEP
ACTION
VALUE(S)
YES
NO
1
•
Key in On Position
•
Test the total battery voltage using a voltmeter
•
Is the total battery voltage greater than 30 VDC?
Go to Step #2
Recharge
Batteries and
Test Power-Up
Circuit Opera-
tion
2
•
Key Off
•
Firmly press circuit breaker 4 to reset
•
Is circuit breaker #4 tripped?
Reset and Test
Power-Up Cir-
cuit Operation
Go to Step #3
3
•
Key On
•
Test voltage applied to the power-up subsystem as
shown on the electrical schematic
•
Are the electrical circuits operating as shown on the
electrical schematic?
Go Back to
Step #1
Identify Volt-
age Drop
Location and
Repair or Re-
place Neces-
sary Compo-
nents
Terms:
VDC = DC Voltage