![Tennant M17 Series Service Information Manual Download Page 161](http://html1.mh-extra.com/html/tennant/m17-series/m17-series_service-information-manual_1086877161.webp)
M17 Service Information 90
17358
(
08
-
20
16)
4-65
TROUBLESHOOTING
Spray Nozzle Failed to Turn ON (Option)
STEP
ACTION
VALUE(S)
YES
NO
1
•
Key On
•
Enable spray nozzle subsystem
•
Is there a
pertinent
f
ault message
displayed?
See
“
Fault Section"
Go to Step #2
2
•
Key Off
•
Firmly press circuit breaker #10 to reset
•
Is circuit breaker #10 tripped?
Reset and Test
Spray Nozzle
Operation
Go to Step #3
3
•
Key O
ff
•
Disconnect spray nozzle water pump from wire har-
ness
•
Apply battery voltage to spray nozzle water pump
using fuse-protected jumper leads
•
Does the spray nozzle water pump dispense water?
Go to Step #4
Repair or
Replace Spray
Nozzle Water
Pump
4
•
Key O
ff
•
Reconnect spray nozzle water pump to wire harness
•
Key On
•
Turn spray nozzle switch On
•
Test voltage applied to spray nozzle subsystem as
shown on the electrical schematic
•
Are the electrical circuits operating as shown on the
electrical schematic?
Go Back to
Step #1
Identify Volt-
age Drop
Location and
Repair or Re-
place Neces-
sary Compo-
nents
Summary of Contents for M17 Series
Page 10: ...1 6 M17 Service Information 9017358 08 2016 SAFETY PRECAUTIONS ...
Page 124: ...4 28 TROUBLESHOOTING M17 Service Information 9017358 08 2016 ...
Page 182: ...4 86 M17 Service Information 9017358 08 2016 TROUBLESHOOTING ...
Page 202: ...5 20 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 203: ...5 21 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 204: ...5 22 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...