M17 Service Information 90
17358
(
08
-
20
16)
4-41
TROUBLESHOOTING
Machine Failed to Propel
STEP
ACTION
VALUE(S)
YES
NO
1
•
Key On
•
See “Curtis 1232SE Controller Diagnostics” section
of this manual
•
Does a Curtis 1232SE controller fault condition
exist?
Correct Fault
Condition
Go to Step #2
2
•
Key O
ff
•
See “Propel Diagnostic Mode”
•
Is P1:Curtis Online?
•
Does P2: Throttle input voltage (0-5 vdc) change
proportionally with throttle pedal movement?
•
Does P3 :Brake pedal input turn On/Off with b
r
ake
pedal activation?
•
Does P4: Direction input correspond with Fwd/Rev
rocker switch position?
•
Does P5:Speed input from drive assembly encoder
(speed, direction, position sensor) read “0000.0
Mph?”
•
Does P8:Propel motor current read “0000.0 Amps?”
•
Is the answer “Yes” to all of the above?
Go to Step #3
Correct Faulty
Input Condi-
tion
3
•
Key O
ff
•
Place machine on jackstands so drive wheel is lifted
off the flo
or
•
Enable forward propel
•
Test voltage applied to the propel subsystem as
shown on the electrical schematic
•
Are the electrical circuits operating as shown on the
electrical schematic?
Go Back to
Step #1
Identify Volt-
age Drop
Location and
Repair or Re-
place Neces-
sary Compo-
nents
Terms:
VDC = Direct Current Voltage
Summary of Contents for M17 Series
Page 10: ...1 6 M17 Service Information 9017358 08 2016 SAFETY PRECAUTIONS ...
Page 124: ...4 28 TROUBLESHOOTING M17 Service Information 9017358 08 2016 ...
Page 182: ...4 86 M17 Service Information 9017358 08 2016 TROUBLESHOOTING ...
Page 202: ...5 20 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 203: ...5 21 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 204: ...5 22 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...