FAULT CODES
Fault Code
Number
Fault Code
(Displayed in LCD)
Fault Code
(Displayed on Pro-Panel Screen)
Cause(s)
Action(s)
0x0127
S Scrub FET
Side Scrub Motor FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0129
S Scrub Tmp
Side Scrub Motor Overheat
1. Motor temperature too high (over 104F).
1. Check motor temp repair or replaced.
0x0131
M Swp 1 Opn
Main Sweep Brush Motor 1 Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0136
M Swp 1 Srt
Main Sweep Brush Motor 1 Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0137
M Swp 1 FET
Main Sweep Brush Motor 1 FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0141
M Swp 2 Opn
Main Sweep Brush Motor 2 Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0146
M Swp 2 Srt
Main Sweep Brush Motor 2 Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0147
M Swp 2 FET
Main Sweep Brush Motor 2 FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0151
R Sweep Opn
Right Sweep Brush Motor Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0156
R Sweep Srt
Right Sweep Brush Motor Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0157
R Sweep FET
Right Sweep Brush Motor FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0161
L Sweep Opn
Left Sweep Brush Motor Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0166
L Sweep Srt
Left Sweep Brush Motor Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0167
L Sweep FET
Left Sweep Brush Motor FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0171
FltShkr Opn
Filter Shaker Motor Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0176
FltShkr Srt
Filter Shaker Motor Short Fault
1. Shorted load condition
2. Some higher current draw than hardware design limit.
1. Check wire harness and repair as needed.
0x0177
FltShkr FET
Filter Shaker Motor FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0230
MSwpAct Flt
Main Sweep Actuator Generic
0x0231
MSwpAct Opn
Main Sweep Actuator Open Warning
1. Wiring, connector or control board issue with circuit to
motor.
1. Check connections, board gets power from key
switch and battery. If connections check out, replace
control board.
0x0237
MSwpAct FET
Main Sweep Actuator FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
0x0240
RSwpAct Flt
Right Sweep Actuator Generic
0x0247
RSwpAct FET
Right Sweep Actuator FET Fault
1. Control board problem.
2. Power/battery issue on startup.
1. Check voltage references.
2. Replace Control Board.
Summary of Contents for M17 Series
Page 10: ...1 6 M17 Service Information 9017358 08 2016 SAFETY PRECAUTIONS ...
Page 124: ...4 28 TROUBLESHOOTING M17 Service Information 9017358 08 2016 ...
Page 182: ...4 86 M17 Service Information 9017358 08 2016 TROUBLESHOOTING ...
Page 202: ...5 20 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 203: ...5 21 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...
Page 204: ...5 22 SERVICE M17 Service Information 9017358 08 2016 PAGE INTENTIONAL LEFT BLANK ...