3-3
6
MAINTENANCE
REPLACING OR ROTATING THE SIDE
SQUEEGEE BLADES
1. If necessary, raise the scrub head.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, set parking brake, and remove key.
2. Open the main brush access door and side
squeegee support door.
3. Unhook the retaining band latch from the side
squeegee assembly.
4. Remove the retaining band from the side
squeegee assembly.
5. Remove the squeegee blade from the side
squeegee assembly.
6. Install the rotated or new rear squeegee blade
onto the side squeegee assembly.
7. Hook the retaining band onto the retaining
band retainer tab on the side squeegee
assembly.
8. Fasten the retaining band latch onto the side
squeegee assembly.
9. Close and secure the squeegee support door
and close the main brush access door.
10. Repeat for the side squeegee on the other side
of the scrub head.