&D - Data Terminal Ready (DTR) Control
Note: if
AT&D2
has been issued and the
DTR
has been tied
Low
, autoanswering is
inhibited and it is possible to answer only issuing command
ATA
.
Note: if parameter is omitted, the command has the same behaviour of
AT&D0
Reference
V25ter
&K - Flow Control
AT&K[<n>]
Set command controls the RS232 flow control behaviour.
Parameter:
<n>
0 - no flow control
3 - hardware bi-directional flow control (both
RTS/CTS
active) (factory default)
Note: if parameter is omitted, the command has the same behaviour as
AT&K0
Note:
&K
has no Read Command. To verify the current setting of
&K
, simply
check the settings of the active profile issuing
AT&V
.
Note: Hardware flow control (
AT&K3
) is not active in command mode.
&S - Data Set Ready (DSR) Control
AT&S[<n>]
Set command controls the RS232
DSR
pin behaviour.
Parameter:
<n>
0 - always
High
1 - follows the traffic channel indication.
2 -
High
when connected
3 -
High
when device is ready to receive commands (factory default).
Note: if option 1 is selected then
DSR
is tied
High
when the device receives from
the network the traffic channel indication.
Note: in power saving mode the
DSR
pin is always tied
Low
& USB_VBUS pin is
always tied Low.
Note:
If parameter is omitted, the command has the same behaviour of
AT&S0.
\R - Ring (RI) Control