LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 155 of 273
#MONI - Cell Monitor
PWR:<dBm>
where:
<netname>
- name of network operator
<cc>
- country code
<nc>
- network operator code
<n>
- progressive number of adjacent cell
<rsrp> -
Reference Signal Received Power
<rsrq> -
Reference Signal Received Quality
<tac> -
Tracking Area Code
<id>
-
cell identifier
<earfcn> -
E-UTRAN Assigned Radio Channel
<dBm>
- received signal strength in dBm
<drx>
- Discontinuous reception cycle length
AT#MONI=?
Test command reports the maximum number of cells, in a neighbour of the serving
cell excluding it, from which we can extract E-UTRAN-related informations, along
with the ordinal number of the current selected cell, in the format:
#MONI: (<MaxCellNo>,<CellSet>)
where:
<MaxCellNo>
- maximum number of cells, in a neighbour of the serving cell and
excluding it, from which we can extract E-UTRAN-related
informations. This value is always
6
.
<CellSet>
- the last setting done with command
#MONI
.
#SERVINFO - Serving Cell Information
AT#SERVINFO
Execution command reports informations about serving cell, in the format:
(E-UTRAN)
#SERVINFO:<EARFCN>,<dBM>,[<NetNameAsc>],<NetCode>,<PhysicalCellId>,
<TAC>,<DRX>,<SD>,<RSRP>
where:
<dBM>
- received signal strength in dBm
<NetNameAsc>
- operator name, quoted string type
<NetCode>
- country code and operator code, hexadecimal representation
<PhysicalCellId>
- Physical Cell ID
<TAC> -
Tracking Area Code
<DRX>
- Discontinuous reception cycle length
<SD>
- Service Domain
0 – No Service
1 – CS Only
2 – PS Only
3 – CS & PS
Summary of Contents for LE910-SKG