Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
53
Deactivated on “OR” function (if at least one
system trouble is present)
4
– Tel. line or communication
failure
5
– Tamper
6
– System bus error
7
– Fire line failure
8
– Siren fault
All system troubles are
enabled by default.
49-54
Not used
-
-
Event No
Special Events - Description
PARAMETERS 1
PARAMETERS 2
55
ENG. MENU
ENTRY
Engineer menu entry
The PGM is activated in Engineer menu
entry.
The PGM is restored in Engineer menu exit.
-
-
56 - 58
Not used
-
-
59
CHIME
EVENT
“Chime” Sound Signal
Activated on “OR” function (there is “Chime”
activated in at least one area)
Deactivation on time - 5 sec.
-
-
60
VIDEO ON
ARMED
Video on armed
Activated in case of violation in an instant
zone with “Video on armed” set option.
Deactivation on time
– 1 minute.
-
-
61
FIRE RESET
Fire Detector Reset
The PGM is activated when the Memory log
file is cleared after entering of valid codes
with rights for operation in the respective
area.
Deactivation on time - 5 sec.
-
-
62
TIME SLOT
Time slot activation
Follows the activation of the respective time
slot number.
Enter a time slot number from
1 to 8.
-
63*
PGM Timer
This only deactivation event. After the set
time is over the PGM is restored.
Enter time in interval 000-255
seconds/ minutes units.
64
CONTROL
Remote control
Remote activation and deactivation
(restore) of the PGM output.
-
-
65
REMOTE
ACCESS
Remote access
Remote Arming and Disarming of the PGM
output via communication module - AJAX,
VD/DTMF, ARGUS and the digital
communicator. Remote control via ProsTE
software.
-
-
66
ALARM OR
ENTRY TIME
Alarm or entry time
-
-
67-72
Not used
-
-
* Note:
The events are not available in revision number 1.8x.
A limited event numbers are available in ECLIPSE 8/ 16 control panel. The panel supports events numbers:
20, 21, 27, 37, 39, 47, 61, 64 and 66. Note that event number 66 is available in ECLIPSE 8/ 16 control panel.