Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
35
Z ABYPASS
ADDRESS
2001
OPERATION
201
TEXT MENU
4. INPUTS – 2. AUTO BYPASS
Number of Activations per Zone for Auto Bypass Mode
The number of activations (number of alarm cycles from 1 to 9) in one arm mode, which have to be
accomplished for a zone with an assigned AUTOBYPASS parameter, are entered at this address.
After reaching the set number of activations, the respective zone will be automatically bypassed.
When disarmed and then again armed the respective zone will remain armed.
The 0 value disables the
Zone AutoBypass mode even if there is set option “1. AUTOBYPASS” at
address
2хх4, where хх is the zone number.
Default setting: [6]
Z INSTANT
ADDRESS
2002
OPERATION
202
TEXT MENU
4. INPUTS – 3. INSTANT
Enabling of Instant type zones
The engineer can enable or disable the intrusion of instant type zones during exit time running at
this address.
Enabling this operating mode would reduce the probability for a false alarm signal to be
triggered off by mistake on behalf of the user.
The parameter status can be changed with pressing of random button of the keyboard.
At this address, you set the parameter as:
DISABLE Disabled intrusion in INSTANT type zones during exit time.
ENABLE
Enables intrusion in INSTANT type zones during exit time.
Default setting: DISABLE
Z PCOUNT
ADDRESS
2003
OPERATION
203
TEXT MENU
4. INPUTS – 4. PULSE COUNT – 1. PULSES
Number of activations in pulse count mode
The number of pulses in Pulse Count mode is assigned at this address.
Values between 1 and 9 pulses can be entered here.
The 0 value blocks the Pulse Count mode and zone can then function with the regular time for
detecting activation.
The working algorithm for zone 4 in Pulse Count mode is described at ADDRESS 2015
– Zone 01
Attributes 2.
Default setting: [0]
Z TPCOUNT
ADDRESS
2004
OPERATION
204
TEXT MENU
4. INPUTS – 4. PULSE COUNT – 2. TIMEOUT
Time for zones in pulse count mode
A time for zones in Pulse Count mode is assigned at this address. Enter a time in interval 0-255 sec.
See also ADDRESS 2015 - Zone 01 Attributes 2 for details.
Default setting: [000]