Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
17
5.3. Enrolling Devices to a working system configuration via LED keyboard
1. Enter engineer code (7777 by default)
– zone numbers 13, 14, 15 and 16 are lighting on. (For LED 8/ 16A –
1, 2, 3 and 4).
2. Enter ADDRESS 8020 and press BYPASS button several times until you reach a free address in the system
–zone numbers from 1 to 16 are lighting on. (For LED 8/ 16A – button “0” is lighting on).
3. Press the ENTER button (for a keyboard) or the tamper-switch (for module, proxy reader or other) of the
device you want to enroll to the system configuration.
4. After successful enrollment to the control panel, the screen displays a lighting on zone number according the
type of the enrolled device (for LED 8/ 16A a lighting button):
Number
Description
ECLIPSE 8*
ECLIPSE 16**
ECLIPSE 32***
1
The main PCB of the control panel
2
Keyboard LCD 32/ 32S
3
Keyboard LED8/ 16/ 32
4
Zone expander
5
PGM expander
6
Wireless expander
7
Proximity card reader
*
Eclipse 8:
Up to 2 devices can be enrolled to the system bus: 2 keyboards, 2 proximity card readers or 1
keyboard and 1 proximity card reader.
**
Eclipse 16:
Up to 5 devices can be enrolled to the system bus irrespective of their type.
***
Eclipse 32:
Up to 31 devices can be enrolled to the system bus irrespective of their type.
NOTE:
It is not necessary to enroll the built-in proximity reader in keyboards LED 32, LCD 32 and LCD 32S.
5. Press ENTER button of the used for programming keyboard. The keyboard will confirm the end of the
successful enrollment procedure with sound signal.
6. The new enrolled device is in normal operation mode and ready for further programming and configuration.
5.4
Deleting of a device from the system configuration
1. Enter engineer code (7777 by default)
2. Enter the address of the device you want to delete from the system configuration.
3. At the respective address press and hold the button
“0” for 2-3 seconds – the LCD shows [Free] for the
address, LED 16/ 32
– LEDs from 1 to 16 are lighting on, LED 8/ 16A – button “0” lights on. A continuous
sound signal is heard.
Attention:
Deleting the unique ID number with button “0” is permanent and you
cannot reject the operation with CANCEL button! To enroll the device again follow the procedure
described at items 5.2 and 5.3.
6. ENGINEER PROGRAMMING
The Engineer programming menus are available only when the system is fully disarmed. By default, the engineer
access code is 7777.
The display performance is different according to the used keyboard model for programming: