Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
75
The following addresses are about the programming of DEVICE 02
– the first added to the system configuration. The
manufacturer recommends that to be a control keyboard.
DEV 02
ID
ADDRESS
8020
OPERATION
810 + 02
TEXT MENU
9. DEVICES – 02. DEVICE [Name] – 1. ID
Identification number for Device 02.
This is an address for enrolling Device 02 to the control panel. It is recommended that to be a LCD
programming keyboard. The following list represents the type of devices available to enroll to the
system configuration:
Indication
LED
Indication
LCD
Description
ECLIPSE
8*
16**
32***
2
LCD
Keyboard LCD 32/ 32S
3
LED
Keyboard LED 8/ 16/ 32
4
ZEXP
Zone expander
5
PEXP
PGM expander
6
WEXP
Wireless expander
7
PRX
Proximity card reader
*
Eclipse 8:
Up to 2 devices can be enrolled to the system bus: 2 keyboards, 2 proxi readers or 1
keyboard and 1 proxi reader.
**
Eclipse 16:
Up to 5 devices can be enrolled to the system bus irrespective of their type.
***
Eclipse 32:
Up to 31 devices can be enrolled to the system bus irrespective of their type.
NOTE:
It is not necessary to enroll the built-in proximity reader in keyboards LED 32, LCD 32 and
LCD 32S.
The steps for enrolling devices to the control panel are described in item 5. Enrolling new devices.
You can also enter the unique ID number of the device directly with the digit buttons and letters:
Digit Button
Letter
Button Combination
0
0
A
/
+ 0
1
1
B
/
+ 1
2
2
C
/
+ 2
3
3
D
/
+ 3
4
4
E
/
+ 4
5
5
F
/
+ 5
6
6
7
7
8
8
9
9
Note: The button
is used in the previous design of the keyboards and has the same
functionality.
To delete the device from the address press and hold the button “0” for 2-3 seconds.
Default setting: LCD/ LED according to the type of enrolled keyboard
DEV 02
AREAS
ADDRESS
8021
OPERATION
811 + 02
TEXT MENU
9. DEVICES – 02. DEVICE [Name] – 2.AREAS
Association of Areas to Device 02
According the system configuration the engineer associates one or several AREA numbers for
operation with Device 02. To select an AREA press the digit button corresponding to its number.
The next pressing of the same button will deselect the AREA. The set configuration for the used
areas is confirmed with ENTER button.
If the device is a proxy card reader, the set at this address area numbers will be armed in Full
arming mode when a valid card is approached and hold in front of the reader until the red
LED lights on.