Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
52
All panic types are enabled
by default.
30*
Panic Alarm in Area
– Restore
Activate on
“AND” function (when all area
numbers are panic alarm restored the PGM
is activated)
Deactivated on
“OR” function (if at least one
area is in panic alarm the PGM is restored)
Enter the panic type:
1
– Silent panic
2
– Sound panic
3
– Silent medical
4
– Sound medical
5
– Fire
All panic types are enabled
by default.
-
31-35
Not used
-
-
Event No
CODE Events - Description
PARAMETERS 1
PARAMETERS 2
36
VALID
CODE
ENTER
Valid User Code Enter
Activated on “OR” function (when a valid
user code is entered the PGM is activated)
Deactivation on time - 5 sec.
Enter the number of user code
to start “FROM”.
Enter the number of user code to
end “TO”.
To set a single user code, enter 00 at the address for
PARAMETERS 2.
To set all possible user codes, enter 00 for both addresses
PARAMETERS 1 and PARAMETERS 2.
37
AMBUSH
CODE
Ambush Code Enter
Activated on “OR” function (when an
ambush code is entered the PGM is
activated)
Deactivation on time - 5 sec.
Enter the number of user code
to start “FROM”.
Enter the number of user code to
end “TO”.
To set a single user code, enter 00 at the address for
PARAMETERS 2.
To set all possible user codes, enter 00 for both addresses
PARAMETERS 1 and PARAMETERS 2.
38
BLOCK KBD
Keyboard Block
Activated when 3 non valid user codes are
entered in sequence.
Deactivation on time - 5 sec.
NOTE: The keyboard blocking must be
enabled at address 0011.
-
-
39
VALID
PROXY
Proximity card using
Only for those cases when the proxy card
and the PGM output have common areas
and at least one of them is disarmed.
Activated on “OR” function (when a valid
proximity card is placed in front of the card
reader the PGM is activated)
Deactivation on time - 5 sec.
Enter the number of proximity
card to start “FROM”.
Enter the number of proximity
card to end “TO”.
To set a single user code, enter 00 at the address for
PARAMETERS 2.
To set all possible user codes, enter 00 for both addresses
PARAMETERS 1 and PARAMETERS 2.
40
INVALID
PROXY
Non valid proximity card using
Deactivation on time - 5 sec.
-
-
41-46
Not used
-
-
Event No
TROUBLE Event - Description
PARAMETERS 1
PARAMETERS 2
47
SYSTEM
FAULT
System Trouble
Activated on “OR” function (if at least one
system trouble is present the PGM is
activated)
Deactivated on “AND” function (when no
system troubles are present )
Enter the trouble type:
1
– AC power loss
2
– Battery loss
3
– Blown fuse
4
– Tel. line or communication
failure
5
– Tamper
6
– System bus error
7
– Fire line failure
8
– Siren fault
All system troubles are
enabled by default.
48*
System Trouble - Restore
Activated on “AND” function (when all
system troubles are restored )
Enter the trouble type:
1
– AC power loss
2
– Battery loss
3
– Blown fuse