Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
74
DEV 01
ID
ADDRESS
8010
OPERATION
810 + 01
TEXT MENU
9. DEVICES – 01. DEVICE [MAIN] – 1. ID
Identification number for Device 01.
The Device 01 is always the control panel
, and it is performed at the LCD display with it is unique
name [MAIN] and ID number. The indication on the LED keyboards is lighting on Zone 01.
This address is only for review.
8010>DEV1_ID
[MAIN][XXXXXXXX]
[MAIN][XXXXXXXX]
Special ID number unique for
every device.
System Name
Name and ID number of the DEVICE 01
Default setting: MAIN
DEV 01
AREAS
ADDRESS
8011
OPERATION
811 + 01
TEXT MENU
9. DEVICES – 01. DEVICE [MAIN] – 2.AREAS
Association of Areas to Device 01
According the system configuration the engineer associates one or several AREA numbers for
operation with Device 01. To select an AREA press the digit button corresponding to its number.
The next pressing of the same button will deselect the AREA.
To select all areas press
button “0” – the button alternatively switches over all enabled / all disabled
state.
Default setting: AREA 1
DEV 01
RESOURSES
ADDRESS
8013
OPERATION
813 + 01
TEXT MENU
9. DEVICES – 01. DEVICE [MAIN] – 4. RESOURCES
On board resources of Device 01.
At this address, the engineer can check the on board resources (number of available zone inputs
and PGM outputs) for Device 01. This address is only for review.
Indication:
LCD 32 (S):
The maximum number of Inputs and Outputs is display on the screen.
LED 32:
The maximum number of Inputs and Outputs are reviewed with the help with the arrows.
When reviewing the Inputs number
the LED “A1” is lighting on, zone 15 is blinking and zone number
from 1 to 8 is showing the number of inputs. When reviewng the Outputs nu
mber the LED “A2” is
lighting on, zone 15 is blinking and zone number from 1 to 8 is showing the number of outputs. Note
that Zone 10 corresponds to no inputs/ outputs available for the device.
LED 8/ 16A:
The maximum number of Inputs and Outputs are reviewed with the help with the
arrows. When reviewing the Inputs number the zone 1 is blinking and a lighting digit button shows
the number of available inputs for the device. When reviewing the Outputs number the zone 2 is
blinking and a lighting digit button shows the number of available outputs for the device.