Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
46
PGM
OPTION
ADDRESS
3000
OPERATION
300
TEXT MENU
5. OUTPUTS – 1. PGM OPTION
Programming the type of PGM 04
The PGM 04 can be configured with different functionality for the ECLIPSE panels at this address.
See the descriptions below to orientate in the available option settings.
PGM 04 in the ECLIPSE 8 control panel can be used as a general programmable output or for serial
connection to TP2000 radio transmitter. The serial link is realized with connection between the AC
terminal of the transmitter and PGM 04 at the control panel.
At this address for ECLIPSE 8 you set the option:
2. SERIAL
LINK
The serial link between the control panel and TP2000 transmitter is enabled. Press
button 2 to enable the option
– the digit is displayed on the LCD screen or lights on
the LED display (for LED8/ 16A button 2 is lighting). Next pressing of the same
button will disable the option
– an asterisk
(
)
is displayed on the LCD screen and
no zone number on the LED display is lighting (for LED8/ 16A button 2 is off).
PGM 04 in the ECLIPSE 32 control panel can be used as a general programmable output or for two-
wire connecting of fire detectors using B24 fire base.
At this address for ECLIPSE 32 you set the option:
1. FIRE
ZONE
The fire zone provides two-wire connection using B24 fire bases. Press button 1 to
enable the option
– the digit is displayed on the LCD screen or lights on the LED
display (for LED8/ 16A button 1 is lighting). Next pressing of the same button will
disable the option
– an asterisk
(
)
is displayed on the LCD screen and no zone
number on the LED display is lighting (for LED8/ 16A button 1 is off).
In case the PGM4 is programmed as fire zone in Eclipse 32 control panel, that zone will be attached
to device 01 (the control panel) as zone number 99. The installer can attach that fire zone to anyone
free zone as at the ADDRESS 2xx0 programs [01] for device and [99] for input/ zone number.
2.2K resistor must be connected at the end of the fire line.
Default: PGM 04 is configured as general output
PGM 01
ATTACH
ADDRESS
3010
OPERATION
310 + 01
TEXT MENU
5. OUTPUTS – 2. PGMs – 01. PGM – 1. ATTACH
Number of device and PGM 01 output number
The installer can review the device number and its input/ output number associated to the output.
The numbers are enter through the digital buttons and confirmed with ENTER.
PGMs from 01 to 05 are the on board outputs on the control panel and they are fixed at
ADDRESSES 3010 to 3050. The contents of ADDRESSES 3010
– 3050 cannot be changed. The
first digit performs the ID number of the device and the second performs the physical output
attached to the PGM number. PGMs 01
– 05 are the physical outputs placed on the control panel so
they are displayed as:
PGM 01: [1] [1]
– The output is attached to the 1
st
output of device 01 (the control panel);
PGM 02: [1] [2]
– The output is attached to the 2
nd
output of device 01 (the control panel), and so on.
PGMs from 06 to 32 can be on board PGM outputs on PGM expander or keyboard (LCD 32 or LCD
32S). The content of ADDRESSES 3060
– 3320 is freely programmable according the system
configuration
– see the examples after this address description.
In the maximal configuration of ECLIPSE 32 can be attached and programmed up to 32 output
numbers
– that depends on the number of used PGM expander modules.
Setting of device and output number for a keyboard or expander module
The LCD 32 and LCD 32S ECLIPSE Series keyboards have and additional PGM output