T3PSX3200P Series User Manual
66
Monitor Function
Description
In order to have well understanding of the
channel under long-term output, the T3PSX3200P
series has the additional live monitor function,
which helps guarantee load status of client via
halting operation based on certain preset
conditions.
Note
This feature is Not applicable to CH3 of T3PS33203P.
Set Monitor
Parameter
Description
Voltage
Set condition of monitor of voltage.
Current
Set condition of monitor of current.
Power
Set condition of monitor of power.
Stop Type
Set status after halt. 3 types are
available, output disable, content notice
and audible alarm.
Select
To confirm if voltage/current/power is
selected as monitor object. White font
stands for selected, while gray font
represents not selected.