REMOTE CONTROL
169
:SYSTem:COMMunicate:LAN:SMASk<mask>
Description
Sets the subnet mask.
Parameter
<mask>
ASCII string, within the range of
1.0.0.0 to 255.255.255.255.
Note
The SYSTem:COMMunicate:LAN:APPLy command
needs to be executed before the subnet mask setting
can take effect.
Example
:SYSTem:COMM:LAN:SMAS 255.255.255.0
Sets the subnet mask to 255.255.255.0.
:SYSTem:COMMunicate:LAN:SMASk?
Description
Query the subnet mask.
Example
:SYSTem:COMMunicate:LAN:SMASk?
Query the subnet mask.
:SYSTem:COMMunicate:LAN:GATEway <IPaddress>
Description
Sets the gateway IP address.
Parameter
<IP address> ASCII string, within the range of
1.0.0.0 to 223.255.255.255 (excluding
127.nnn.nnn.nnn).
Note
The SYSTem:COMMunicate:LAN:APPLy command
needs to be executed before the gateway IP address
setting can take effect.
Example
:SYSTem:COMMunicate:LAN:GATEway 172.16.3.1
Sets the gateway IP to 172.16.3.1.
Summary of Contents for T3PS13206P
Page 1: ... ...
Page 106: ...T3PSX3200P Series User Manual 106 Register Commands OPC 187 OPC 187 ...
Page 177: ...REMOTE CONTROL 177 Example SAV 1 Recalls the setting stored in memory 2 STATE02 ...
Page 185: ...REMOTE CONTROL 185 Example STB Returns 81 if the status byte register is set to 0101 0001 ...
Page 196: ...T3PSX3200P Series User Manual 196 Between chassis and DC power cord 30MΩ or above DC 500V ...