OVERVIEW
11
Load Mode
The T3PSX3200P series models have additional
Load function on both CH1 & CH2 with 3 modes:
CV (Constanct Voltage), CC (Constant Current)
and CR (Constant Resistance), all of which can be
selected through the function keys on the front
panel. Voltage, current and resistance can be well
regulated in each mode, respectively.
Constant Voltage/
Constant Current
Each output channel works in constant voltage
(CV) or constant current (CC) mode. Even at the
maximum output current, a fully rated,
continuously adjustable output voltage is
provided. For a big load, the power supply can be
used as a CV source; while for a small load, a CC
source. When in the CV mode (independent or
tracking mode), output current (overload or short
circuit) can be controlled via the front panel. When
in the CC mode (independent mode only), the
maximum (ceiling) output voltage can be
controlled via the front panel. The power supply
will automatically cross over from CV to CC
operation when the output current reaches the
target value. The power supply will automatically
cross over from CC to CV when the output voltage
reaches the target value. For more details about
CV/CC mode operation, see page 24.
Automatic
tracking mode
The front panel display (CH1, CH2) shows the
output voltage or current. When operating in the
tracking mode, the power supply will
automatically connect to the auto- tracking mode.
Display Change
Function
The T3PSX3200P series provides up to 7 display
types, each of which can be selected via setting.
For details, see page
Summary of Contents for T3PS13206P
Page 1: ... ...
Page 106: ...T3PSX3200P Series User Manual 106 Register Commands OPC 187 OPC 187 ...
Page 177: ...REMOTE CONTROL 177 Example SAV 1 Recalls the setting stored in memory 2 STATE02 ...
Page 185: ...REMOTE CONTROL 185 Example STB Returns 81 if the status byte register is set to 0101 0001 ...
Page 196: ...T3PSX3200P Series User Manual 196 Between chassis and DC power cord 30MΩ or above DC 500V ...
Page 197: ... 0 0 0 1 2 3 4 5 6 7 8 8 9 3 3 3 45 6 990 0 0 9 0 0 0 9 0 0 0 0 9 7 7 88 8 1 931711 RevB ...