T3PSX3200P Series User Manual
126
Example
:DELAy2:PARAmeter? 2,2
Return the delay parameter of 2 groups of Delay
for CH2. From the second group.
The format of delay parameter of each group is
“serial number, output state, delay duration”, and
every group of parameter is divided by
semicolon“;”. For instance, “2, OFF, 3;3, ON,1;”
representing the delay parameters of 2 groups; the
serial number of delay parameter of the 1st group
is 2, output state is OFF,delay time is 3S;the 2nd
group is 3, output state is ON,delay time is 1S.
:DELAy [1|2]:STARt <value>
Description
Sets the sequence number for initial execution.
Parameter
<NRf> 0 - 2047
Example
:DELAy2:STARt?
Sets the CH2 sequence output to start from the
group 10.
:DELAy [1|2]:STARt?
Description
Queries the sequence number for initial execution
of the channel delay output.
Example
:DELAy 2:STARt?
Returns the initial sequence number of CH2
sequence output.
:DELA y[1|2] [:STATe]{ON|OFF}
Description
Enable or disable the delay output function of the
active channel.
Parameter
ON
OFF
Output state of the group
Summary of Contents for T3PS13206P
Page 1: ... ...
Page 106: ...T3PSX3200P Series User Manual 106 Register Commands OPC 187 OPC 187 ...
Page 177: ...REMOTE CONTROL 177 Example SAV 1 Recalls the setting stored in memory 2 STATE02 ...
Page 185: ...REMOTE CONTROL 185 Example STB Returns 81 if the status byte register is set to 0101 0001 ...
Page 196: ...T3PSX3200P Series User Manual 196 Between chassis and DC power cord 30MΩ or above DC 500V ...
Page 197: ... 0 0 0 1 2 3 4 5 6 7 8 8 9 3 3 3 45 6 990 0 0 9 0 0 0 9 0 0 0 0 9 7 7 88 8 1 931711 RevB ...