T3PSX3200P Series User Manual
114
:OUTPut[1|2|3|4]:OCP:STATe?
Description
Queries the status of the OCP function.
Example
:OUTPut2:OCP:STATe?
Returns the status of the OCP function on CH2.
:OUTPut[1|2|3|4]:OCP <value>
Description
Sets the OCP level.
Parameter
< value >
CH1 0.05-3.50A
CH2 0.05-3.50A
CH3 0.05-1.20A(T3PS43203P)
CH4 0.05-1.20A(T3PS43203P)
Example
:OUTPut2:OVP 1.5
Sets the OVP voltage to 1.5A for CH2
:OUTPut[1|2|3|4]:OCP?
Description
Queries the OCP current level.
Example
:OUTPut2:OCP?
Queries the OCP current level on CH2.