REMOTE CONTROL
135
:MONItor[1|2|3|4]:VOLTage[:VALue]{<value>|MINimum
|MAXimum}
Description
Sets the voltage monitor value of monitor (active
channel)
Parameter
<value> Ranges from 0 to the maximum voltage
value of the active channel.
Example
:MONItor2: VOLTage 5
Sets the CH2 voltage monitor value of monitor as
5V (active channel).
:MONItor[1|2|3|4]:VOLTage[:VALue]?
Description
Queries the voltage monitor value of monitor
(active channel).
Example
:MONItor2: VOLTage?
Queries the CH2voltage monitor value for the
current monitor.
:RECOrder[1|2|3|4]:PATH?
Description
Queries the save location of recorded file
Example
:RECOrder2:PATH?
Queries the save location of recorded file for CH2.
:RECOrder[1|2|3|4]:MEMory{0|1|2|3|4|5|6|7|8|9}
Description
Save the recorded file with specified name to the
internal storage with specified saving location.
Parameter
{
0|1|2|3|4|5|6|7|8|9
}
represents 10 individual
saving locations of recorded file within internal
storage.
Summary of Contents for T3PS13206P
Page 1: ... ...
Page 106: ...T3PSX3200P Series User Manual 106 Register Commands OPC 187 OPC 187 ...
Page 177: ...REMOTE CONTROL 177 Example SAV 1 Recalls the setting stored in memory 2 STATE02 ...
Page 185: ...REMOTE CONTROL 185 Example STB Returns 81 if the status byte register is set to 0101 0001 ...
Page 196: ...T3PSX3200P Series User Manual 196 Between chassis and DC power cord 30MΩ or above DC 500V ...