Installation, Outdoor HPO PowerMAX System
215861 REV C
57
3.2.4 Install Optional Maintenance Switch
After all amplifiers and waveguide/combiner arrays have been installed, the optional
Maintenance Switch may be installed at the system RF output.
Attach the Maintenance Switch support to the adjacent uni-strut, using the hardware
provided. The mounting hardware was shipped in place from the factory.
Connect the Maintenance Switch at the RF Output of the 16-way system, just after the
dual crossguide coupler connected to the magic tee.
Insert an appropriately sized full gasket (provided) in the grooved flange of the
crossguide coupler. Connect the waveguide flange of the single crossguide coupler to
the flange of the dual crossguide coupler, as shown in
Figure 3-26
.
Figure 3-26: Installation, Optional Maintenance Switch