Nevertheless, you need another program because you want to
move the sampler to site B, so you select “EXTENDED 2” and
modify it for site B. The settings in “EXTENDED 1” are pre
-
served automatically. When you return the sampler to site A, you
won’t need to reprogram the sampler. Merely select “EXTENDED
1” again, double-check the program settings, and run the
program. To select an extended program, follow the steps in the
example “
Selecting a Stored Extended Program
.”
5.4 Programming for 700
Series Modules
The bay on the controller’s side accepts any of Teledyne ISCO’s
700 Series Modules. These optional accessories are not required
to operate the sampler. However, the modules offer an economical
way to combine flow-rate or parameter monitoring with sam-
pling.
The programming of these modules is integrated with the pro-
gramming of the sampler, so attachment of a module will cause
different screens to be displayed, depending on the type of
module and the selections you make while programming.
Two modules that are commonly used are the 730 Bubbler
Module, which monitors a flow stream’s level and flow rate, and
the 750 Area Velocity Module for monitoring a flow stream’s
level, velocity, and flow rate. Section 4 contains two examples of
programming for modules. Module programming is the same in
Extended as it was in Standard programming.
5.5 Programming
Examples
In addition to the features available with standard programming
which are discussed in Section 4, extended programming offers:
•
Nonuniform time pacing
•
Random interval pacing
•
Event pacing
•
Multiple bottle compositing
•
Time switched bottles or bottle sets
•
Flow proportional sample volumes
•
Programmable sampler enable
•
Pauses and resumes
•
Two-part programming
•
Automatic or user-defined suction head
•
Suction line rinses
•
Sampling retries
This manual provides several programming examples. Some,
demonstrating simple tasks, appear in the margins. Others,
demonstrating more complex tasks, appear as examples. The
example “
Storm Water Runoff Sampling Program
” steps you
through a storm water runoff sampling using extended pro-
gramming.
Summary of Contents for Everywhereyoulook BLZZRD
Page 2: ......
Page 4: ......
Page 8: ...BLZZRD Portable Refrigerated Sampler Safety vi ...
Page 16: ...BLZZRD Portable Refrigerated Sampler Table of Contents xiv ...
Page 34: ...BLZZRD Portable Refrigerated Sampler Section 1 Introduction 1 18 ...
Page 58: ...BLZZRD Portable Refrigerated Sampler Section 2 Installation Preparation 2 24 ...
Page 72: ...BLZZRD Portable Refrigerated Sampler Section 3 Programming Introduction 3 14 ...
Page 88: ...BLZZRD Portable Refrigerated Sampler Section 4 Standard Programming 4 16 ...
Page 219: ...BLZZRD Portable Refrigerated Sampler Appendix B Material Safety Data Sheets B 8 ...
Page 233: ...BLZZRD Portable Refrigerated Sampler Appendix D Replacement Parts D 6 ...
Page 241: ...BLZZRD Portable Refrigerated Sampler Appendix F Battery Selection Guide F 4 ...