BLZZRD Portable Refrigerated Sampler
Section 5 Extended Programming
5-27
If you select “NO” when asked if you want to reset the sample
interval at enable, you will be asked if you want to continue the
countdown while disabled. You can have the sampler continue
the countdown, repeating it as often as necessary while the
sampler is disabled, or you may suspend the countdown while
disabled, resuming the countdown as the sampler is enabled. The
standard program allows the countdown to continue while dis-
abled.
5.12 Pauses/Resumes
Pause and resume settings, available in extended programming,
create an intermittent sampling schedule. A program with
pauses and resumes begins sampling at its programmed start
time, continuing until the first pause time and day of the week. It
then suspends sampling until the first resume time, when it
begins sampling again. If the start time falls within a pause
period, the sampler will not begin sampling until the next
resume time. Pause and resumes repeat weekly.
You can enter up to nine pairs of pause and resume times. The
pause and resume times shown as examples below suspend the
program between 5:00
PM
Monday and 8:00
AM
on Tuesday and
between 5:00
PM
Tuesday and 8:00
AM
on Wednesday. If the start
time is Monday at 8:00
AM
, the sampler takes samples between
8:00
AM
and 5:00
PM
Monday; between 8:00
AM
and 5:00
PM
Tuesday; and, continues after 8:00
AM
Wednesday. To remove
pause and resume settings from a program, select CLEAR.
A sampler running a pause/resume program resets the pacing
interval at each resume time. You can program the sampler to
take a sample at resume times.
5.13 Running Programs
To run an extended program, select run from the main menu.
You may also select YES at the RUN THIS PROGRAM NOW?
screen at the end of the programming screens.
Extended programs scheduled to start at a clock time will not
start until the programmed clock time on or after the first valid
date.
CONTINUE COUNTDOWN
WHILE DISABLED?
YES
NO
PAUSE RESUME
1. 17:00 MO
08:00 TU
2. 17:00 TU
08:00 WE
CLEAR DONE
SAMPLE AT RESUME?
YES
NO
Summary of Contents for Everywhereyoulook BLZZRD
Page 2: ......
Page 4: ......
Page 8: ...BLZZRD Portable Refrigerated Sampler Safety vi ...
Page 16: ...BLZZRD Portable Refrigerated Sampler Table of Contents xiv ...
Page 34: ...BLZZRD Portable Refrigerated Sampler Section 1 Introduction 1 18 ...
Page 58: ...BLZZRD Portable Refrigerated Sampler Section 2 Installation Preparation 2 24 ...
Page 72: ...BLZZRD Portable Refrigerated Sampler Section 3 Programming Introduction 3 14 ...
Page 88: ...BLZZRD Portable Refrigerated Sampler Section 4 Standard Programming 4 16 ...
Page 219: ...BLZZRD Portable Refrigerated Sampler Appendix B Material Safety Data Sheets B 8 ...
Page 233: ...BLZZRD Portable Refrigerated Sampler Appendix D Replacement Parts D 6 ...
Page 241: ...BLZZRD Portable Refrigerated Sampler Appendix F Battery Selection Guide F 4 ...