Operating Instructions
Model 200E Instruction Manual
Table 6-17: COM Port Communication Modes
Mode ID
Description
Quiet mode
1
Quiet mode suppresses any feedback from the analyzer (iDAS reports, and
warning messages) to the remote device and is typically used when the port
is communicating with a computer program such as APICOM. Such feedback
is still available but a command must be issued to receive them.
Computer
mode
2
Computer mode inhibits echoing of typed characters and is used when the
port is communicating with a computer program, such as APICOM.
Security
mode
4
When enabled, the serial port requires a password before it will respond. The
only command that is active is the help screen (? CR). Section 6.4.1 describes
the password functionality.
Enable
Internet
8
Enables the use and configuration of the Ethernet interface. When enabled, a
new menu item INET will appear in the respective COM port menu.
Hessen
protocol
16
The Hessen communications protocol is used in some European countries. T-
API part number 02252 contains more information on this protocol.
Multidrop
Protocol
32
Multidrop protocol allows a multi-instrument configuration on a single
communications channel. Multidrop requires the use of instrument IDs.
Enable
modem
64
Enables to send a modem initialization string at power-up. Asserts certain
lines in the RS-232 port to enable the modem to communicate.
Ignore
Errors
128
Fixes certain types of parity errors at certain Hessen protocol installations.
Disable
XON/XOFF
256
Disables XON/XOFF data flow control.
512
Unused
RS-485
mode
1024 Configures the COM2 Port for RS-485 communication. RS-485 mode has
precedence over multidrop mode if both are enabled.
E, 7, 1
2048 This setting selects even parity, 7 data bits, and 1 stop bit for this com port;
the default setting is always no parity, 8 data bits, and 1 stop bit. Used in
conjunction with the Hessen protocol, hence, it is listed after ID 16
Command
Prompt
4096 Enables a command prompt when in terminal mode.
Each Parameter is preceded by a string of either
COM1
or
COM2
depending on the chosen
COM port.
78
044100102 Rev A
Summary of Contents for 200E
Page 15: ...M200E Documentation Model 200E Instruction Manual USER NOTES xiv 044100102 Rev A ...
Page 19: ...M200E Documentation Model 200E Instruction Manual USER NOTES 4 044100102 Rev A ...
Page 141: ...Calibration Procedures Model 200E Instruction Manual USER NOTES 126 044100102 Rev A ...
Page 203: ...Theory of Operation Model 200E Instruction Manual USER NOTES 188 044100102 Rev A ...
Page 239: ...Troubleshooting Repair Model 200E Instruction Manual USER NOTES 224 044100102 Rev A ...
Page 265: ...APPENDIX A Model 200E Instruction Manual USER NOTES 250 044100110 Rev A ...
Page 271: ...APPENDIX B Model 200E Instruction Manual USER NOTES 256 044100120 Rev A ...
Page 275: ...APPENDIX D Model 200E Instruction Manual 260 044100141 Rev A USER NOTES ...