Spectrum Analysis (S/A Mode)
WCA230A & WCA280A User Manual
3- 11
The OBW (Occupied Bandwidth) measures the frequency bandwidth, using the
ratio you specify for carrier signal power / power within the span setting.
Meas Setup Menu.
The Meas Setup menu for the OBW measurement contains the
following control.
Power Ratio.
Specifies the power ratio of the carrier and span regions for
calculating OBW (see Figure 3--10). The default setting is 99% as defined in
T--53 or IS--95 standard. Range: 80 to 99.99%.
Power Ratio = (Cp/Sp)
¢
100
Cp: Power of carrier region
Sp: Power of span region
Figure 3- 10: OBW measurement band power marker