Appendix B: Automatic Measurements Reference
B- 26
CSA8000B & TDS8000B User Manual
Table B- 4: RZ Measurements - Amplitude (cont.)
Name
Definition
RZ Suppression Ratio
The ratio of the average power level of the logic High to the Suppressed level measured
between two consecutive RZ pulses. The RZ pulse is sampled within the Eye Aperture where
the High is determined as the mean of the histogram of the data distribution in the upper half of
the pulse. The same region is sampled to record the data distribution in the lower half of the
pulse, data corresponding to the logical level 0. Similarly, data is sampled in an equivalent sized
region placed at one-half bit interval offset from the Eye Aperture. The mean of the histogram of
the data distribution between the peaks adjusted by subtracting the zero level histogram yields
the Suppressed level.
Where:
H
High and Low are the logical 1 and 0 levels
H
Suppress is the mean of the histogram of the data within an Eye Aperture in the
suppressed region
The Eye Aperture is adjustable and defaults to 5% of the RZ pulse width. See
RZ Eye Aperture
Parameters
on B--62.
If enabled, measurement gates constrain the measurement region to the area between the Start
Gate (G1) and Stop Gate (G2). The region used for sampling the suppressed region is equal to
the Eye Aperture and has no independent control. See
To Localize a Measurement
on
page 3--83.
This measurement requires the use of a waveform database. When this measurement is turned
on, it will automatically set the measurement system to use a waveform database if available.
See
Use a Waveform Database
on page B--70.
For best measurement results:
H
Perform a Dark Level compensation before taking this measurement. See
To Perform
Dark-Level and User Wavelength Gain Compensations
on page 3--98.
H
Optimize the vertical resolution before taking this measurement. See
How to Optimize the
Vertical Resolution
on page B--70.
RZ Suppression Ratio
=
High
(
Suppress
−
Low
)
Summary of Contents for CSA8000B Series
Page 4: ......
Page 18: ...Preface xiv CSA8000B TDS8000B User Manual ...
Page 26: ...Check the Package Contents 1 8 CSA8000B TDS8000B User Manual ...
Page 62: ...Accessories and Options 1 44 CSA8000B TDS8000B User Manual ...
Page 76: ...Overview 3 2 CSA8000B TDS8000B User Manual ...
Page 112: ...Acquiring Waveforms 3 38 CSA8000B TDS8000B User Manual ...
Page 126: ...Triggering 3 52 CSA8000B TDS8000B User Manual ...
Page 146: ...Displaying Waveforms 3 72 CSA8000B TDS8000B User Manual ...
Page 174: ...Measuring Waveforms 3 100 CSA8000B TDS8000B User Manual ...
Page 186: ...Creating Math Waveforms 3 112 CSA8000B TDS8000B User Manual ...
Page 214: ...Data Input and Output 3 140 CSA8000B TDS8000B User Manual ...
Page 353: ......
Page 354: ......