Trigger Setup
For I
2
C, push the lower-bezel
Trigger On
to trigger on
Address/Data
. Push
Address
. On the side-bezel menu, push
Address
,
and rotate multipurpose knobs
a
and
b
as needed. Set the address to don’t cares (X) if you want to mask the address. The
data will be matched starting at the
fi
rst byte without using a rolling window.
For CAN, triggering occurs when the user-selected data input matches the data and quali
fi
er in the signal starting at the
fi
rst
byte. Set the number of bytes to match the number of bytes of interest. Use the data quali
fi
er to perform: =, !=, <, >, >=,
and <= operations. Triggering on identi
fi
er and data always matches the identi
fi
er and data selected by the user, with the
data starting at the
fi
rst byte. No rolling window is used.
140
Tektronix 4000 Series Oscilloscopes User Manual
Summary of Contents for 4000 Series
Page 4: ......
Page 18: ...Preface xiv Tektronix 4000 Series Oscilloscopes User Manual ...
Page 53: ...Installation 2 Power off your oscilloscope Tektronix 4000 Series Oscilloscopes User Manual 35 ...
Page 68: ...Installation 50 Tektronix 4000 Series Oscilloscopes User Manual ...
Page 312: ...Application Examples 294 Tektronix 4000 Series Oscilloscopes User Manual ...