The PWM factor of the 12 outputs is set in CV48-59 (see The decoder CV table).
CV112 is controlling the start-up time (Fade-IN), respectively CV113, the fall-off time (Fade-OUT) of
the PWM signal applied to outputs. These times can be set in steps of 8ms and represent the time in which
the output PWM fill factor rise from 0 to 255, or vice versa. If CV48-59 establishes a fill factor lower than
the maximum value 255, the rise and fall times decrease proportionally. These two parameters are common
to all outputs. This function is useful when we want to simulate the slow turn on of incandescent bulbs.
If we want any output to be commanded with a continuous signal (without variable fill factor PWM) in
CV117(CV185) we can set to value 1 the bit corresponding to the desired output(s). On Lokommander II
versions with more than 8 outputs, the continuous command of outputs 9-12 can be set from CV185 bits 0-3.
Starting with software version 3.5.207, functions F0 (f / r), F1 (f / r) and F2-F12 can be configured to
inhibit one or more output(s) FL, RL, AUX1, ... AUX 6.