Lokommander II Next18 ECU
User Manual firmware 5.10.306
Version 0.5.07
Page 66 of 118
CV
Default
Value
Value
Range
Description
27
0
0-7
Decoder Automatic Stopping Configuration (see 12)
Bit0 = 0(0) Disable Auto Stop in the presence of an asymmetrical DCC
signal which is more positive on the right rail
= 1(1) Enable Auto Stop in the presence of an asymmetrical DCC
signal which is more positive on the right rail
Bit1 = 0(0) Disable Auto Stop in the presence of an asymmetrical DCC
signal which is more positive on the left rail
= 1(2) Enable Auto Stop in the presence of an asymmetrical DCC
signal which is more positive on the left rail
Bit2
–
not used.
Bit3
–
not used.
Bit4 = 0(0) Disable Auto Stop in the presence of reverse polarity DC
= 1(16) Enable Auto Stop in the presence of reverse polarity DC
Bit5 = 0(0) Disable Auto Stop in the presence forward polarity DC
= 1(32) Enable Auto Stop in the presence forward polarity DC
Bit6
–
not used.
Bit7 = 0(0) Disable Auto Stop in the presence of zero speed brake
= 1(128) Enable Auto Stop in the presence of zero speed brake