Lokommander II Next18 ECU
User Manual firmware 5.10.306
Version 0.5.07
Page 34 of 118
12.4.
Special brake functions
The locomotive can be stopped, only slowed down, or the deceleration rate can be altered, activating one
or more of the configurable three special brake functions. The functions number can be set in CV197,
CV198 and CV199. By default this CVs have the value 255, meaning that no function key will activate this
special
brake functions. The possible range is F0 … F28
(CV values: 0-28).
Activating one of the configured special brake functions, will have the following results:
-
The deceleration rate from CV4 will be reduced with a percentage configured in CV
200 … CV202,
corresponding for each brake function. The default value of these CVs is zero. Value zero means no
reduction and value 255 means 100% reduction. If more brake functions are activated simultaneously
the corresponding reduction percentage will be cumulated, without exceeding 100%.
-
The
locomotive speed will be reduced to a maximal value set in CV203 … CV205 corresponding for
each brake function. The default value for these CVs is zero, meaning that locomotive will stop if
any brake function is activated. If the actual speed is lower than the activated brake speed, no speed
change will occur. If more brake functions are activated, the lower speed will be considered.
If consist mode is used, the brake functions will be active for the decoder individual address.