Lokommander II Next18 ECU
User Manual firmware 5.10.306
Version 0.5.07
Page 88 of 118
CV
Default
Value
Value
Range
Description
118 8
0-12
Electrical Coupler Output mapping. Only one of the outputs can be configured
as ECoupler Output
CV118 = 0, None of the AUX selected for ECoupler operation
CV118 = 1, FL selected for ECoupler operation
CV118 = 2, RL selected for ECoupler operation
CV118 = 3, AUX1 selected for ECoupler operation
…….
CV118 = 12, AUX10 selected for ECoupler operation
119 50
0-255 Travel time T1 in the first phase of automatic decoupling (8ms steps)
ex: CV119 = 50; 50 * 8ms = 400ms (see 17)
120 50
0-255 Travel time T2 in the second phase of automatic decoupling (8ms steps)
ex: CV120 = 50; 50 * 8ms = 400ms (see 17)
121 30
0-255 Locomotive speed during automatic decoupling. CV121 = 0 means speed zero
(see 17)