9.3.6 Sprayer geometry
For correct functions of automatic section control and ratio regulation edit correctly geometrical
parameters related to the sprayer implement where it is mounted. The following image describes
the meanings of each parameter.
Figure 17
A.
Connector reference point (joint)
B.
Device reference point (implement axle middle point)
C.
Boom center
According to the above schema set the following parameters in the SETUP page:
a.
“
Y Offset
”
(positive to the right and negative to the left)
b.
“
Connector distance
”
(set to 0 for a mounted sprayer / shall be different from 0 for a
trained one)
c.
“Boom distance”
d.
“
Section 1
width”
(every section may have different width)
Consider that the above geometrical parameter may or not be used by the Task Controller (TC).of
the Virtual terminal VT. Some TC allows the setting of these parameters with own specific user
interface and in this case, it is not sure that the ones received form ISOBUS ECU 1224 will be
actualized (may depends on TC settings). Verfy documentation of your Virtual Terminal
9.3.7 Date-time from tractor TECU
The “Clock enable” parameter of the SETUP page (refer to figure 13), allows the use or not of the
date-time information that may be received from the tractor TECU (Tractor Electronic Control
Unit). Not all TECU support this option.
Summary of Contents for GEOline 8410073
Page 1: ......
Page 63: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 62 ...
Page 64: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 63 ...
Page 65: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 64 ...
Page 66: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 65 ...
Page 67: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 66 ...
Page 68: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 67 ...