ISOBUS ECU 1224 User and Instruction maual
|
P00801545 Rev:02 SW:1.0.0
43
•
Define the Rate (liters/ha) set-point to be maintained during the treatment (can be
manually changed during the spraying operation)
•
Define the sections of the boom to be open/closed
All the above actions can be performed using the controls contained in the WORK page.
10.4.2 Automatic Mode
This function shall be activated by the user only if your Virtual Terminal includes a Task Controller.
Refer to Figure 19 for a representation of the WORK page in this modality.
In this case the following actions are directly managed by the Task Controller included in your
Virtual Terminal.
•
Define the rate (liters/ha) set-point.
•
Define the sections of the boom to be open/closed according to GPS position and
overlap. In automatic mode the keys dedicated to change the flow-rate set-point are
hidden; so, the user is not able to do any change on this value.
The key
open/close boom and sections remain available. User can interrupt spraying
using this key
In Automatic Mode if VT/TC can handle prescription map and Automatic Section Control, ISOBUS
ECU 1224 can spray with a flow-rate set-point variable according to the position of the sprayer in
the field and automatically open/close the boom sections when the field boundaries are reached
or an overlap is detected.
If your Virtual Terminal does not include a Task Controller or it is not enabled, the ISOBUS ECU
1224 signals to the user this situation showing the automatic icon of the WORK page with an
overlapped red X, as indicated in the following image 33
Summary of Contents for GEOline 8410073
Page 1: ......
Page 63: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 62 ...
Page 64: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 63 ...
Page 65: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 64 ...
Page 66: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 65 ...
Page 67: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 66 ...
Page 68: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 67 ...