ISOBUS ECU 1224 User and Instruction maual
|
P00801545 Rev:02 SW:1.0.0
17
8.3 Flowmeter installation
The flowmeter is directly connected to ISOBUS ECU 1224 and measure flow in the control unit
during a spraying treatment, it shall be correctly configured in the SETUP page of the user
interface (refer to Flowmeter setup Chapter 9.3.2)
The flowmeter shall be provided with a cable terminating with a 3-poles male connector, that will
be plugged with the related female of the connection cable provided with ISOBUS ECU 1224.
Sensor input plug is part of harness Connector C2 (Gray connector 24 pin),
Label “F”
The pinout of the female connector provided with the ISOBUS ECU 1224 driver cable is the
following
Table 8
PIN
Description
Color
1
GND
BLACK
2
Power
RED
3
Signal
GREEN
8.4 Pressure sensor installation
The pressure sensor is optional. can be used for pressure measure or flow regulation. For specific
applications, user can decide to use Pressure sensor instead of flow sensor.
Sensor is connected to the ISOBUS ECU 1224 and can measure the liquid pressure during a
spraying treatment, it shall be correctly configured in the SETUP page of the user interface (refer
to chapter 9)
The pressure sensor shall be provided with a cable terminating with a 3-poles male connector, that
will be plugged with the related female of the connection cable provided with the ISOBUS ECU
1224. Sensor input plug is part of harness Connector C2 (Gray connector 24 pin), l
abel “P”
The pinout of the female connector provided with the ISOBUS ECU 1224 driver cable is the
following
Table 9
PIN
Description
Color
1
GND
BLACK
2
Power
RED
3
Signal
GREEN
8.5 Tank-level sensor installation
The tank-level sensor is optional. Level sensor is noyt used for rate regulation. Level sensor is
directly managed by the ISOBUS ECU 1224 driver and if installed to manage the detection of the
Summary of Contents for GEOline 8410073
Page 1: ......
Page 63: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 62 ...
Page 64: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 63 ...
Page 65: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 64 ...
Page 66: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 65 ...
Page 67: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 66 ...
Page 68: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 67 ...