Setting up audio and syncing
UpCon English Manual (2014-10-07) 54
Sync Source
Settings: AES 1/2, AES 3/4, AES 5/6, AES 7/8,
AES 9/10, AES 11/12, AES 13/14, AES 15/16*
Use the Sync Source parameter to select the
signal source that UpCon should sync to.
Please note that channel pairs from 9/10 to 15/16
are only available as Sync Sources when you
have the optional AES 16ch license. For more
information, see “Extending your product’s ca-
pabilities with optional licenses” on page 100.
When the Clock Master parameter is set to “In-
ternal”, the Sync Source setting is irrelevant.
However, you should be aware that you can use
this parameter to pre-select a sync source that
will be used when you switch UpCon AES direct-
ly from Internal to External Sync.
Advanced Mode section (AES)
The Advanced AES Mode section contains ad-
ditional AES-related settings.
Fig. 27.: I/O setup – AES page (UpCon AES)
with Advanced settings activated
Advanced settings switch
To change advanced AES settings, click the Ad-
vanced button in the Advanced Mode section of
this page.
! Please note that switching off access to Ad-
vanced AES settings will reset all parameters
in this section to their default values.
Clock Master parameter
Settings: External (default), Intern. 48 kHz
Use the Clock Master parameter to set whether
UpCon should be referencing an incoming ex-
ternal clock source or an internal crystal running
at 48 kHz.
►
External reference is mandatory in a broad-
cast installation and therefore the default set-
ting.
►
Internal is typically only for test and labora-
tory use.
Clock Fallback parameter
Settings: Freewheel (default), Halt
Use the Clock Fallback parameter to set how the
internal clock of UpCon should be applied when
the external sync source is not present.
►
Freewheel:
When sync is lost and the Clock
Fallback parameter is set to Freewheel, the
UpCon will continue running on the “last good
rate”. If possible, UpCon will run on a 96 bit
precision version of the last good sample rate
that the UpCon received. This will only gener-
ate few sample slips downstream and on the
inputs (which may still receive audio) so the
audio quality is not significantly reduced. In
some borderline cases it may not be possible
to calculate the last good incoming sample
rate. In such a situation, the UpCon will revert
to the internal 48 kHz clock and audio will still
be sent through. Expect more sample slips in
such a situation.
►
Halt:
When the sync source is not present
and the Clock Fallback parameter is set to
Halt, all AES outputs are turned off – meaning
no audio data and no AES carrier (no clock)
are being sent out. Use this setting if you pre-
fer to stop audio and clock output completely
Summary of Contents for UpCon
Page 4: ...Important safety instructions UpCon English Manual 2014 10 07 1 Important safety instructions...
Page 8: ...About this manual UpCon English Manual 2014 10 07 5 About this manual...
Page 10: ...Before you get started UpCon English Manual 2014 10 07 7 Before you get started...
Page 12: ...Unpacking and setup UpCon English Manual 2014 10 07 9 Unpacking and setup...
Page 20: ...UpCon An introduction UpCon English Manual 2014 10 07 17 UpCon An introduction...
Page 34: ...Setting up UpCon UpCon English Manual 2014 10 07 31 Setting up UpCon...
Page 40: ...Basic operation UpCon English Manual 2014 10 07 37 Basic operation...
Page 45: ...Accessing UpCon UpCon English Manual 2014 10 07 42 Accessing UpCon...
Page 52: ...Setting up audio and syncing UpCon English Manual 2014 10 07 49 Setting up audio and syncing...
Page 59: ...UpCon remote control UpCon English Manual 2014 10 07 56 UpCon remote control...
Page 77: ...Updating UpCon firmware UpCon English Manual 2014 10 07 74 Updating UpCon firmware...
Page 84: ...Icon Setup UpCon English Manual 2014 10 07 81 Icon Setup...
Page 90: ...The UpCon algorithm UpCon English Manual 2014 10 07 87 The UpCon algorithm...
Page 100: ...The UpCon algorithm UpCon English Manual 2014 10 07 97...
Page 104: ...Appendix 2 UpCon GPI O page UpCon English Manual 2014 10 07 101 Appendix 2 UpCon GPI O page...
Page 107: ...Technical specifications UpCon English Manual 2014 10 07 104 Technical specifications...
Page 114: ...Technical specifications UpCon English Manual 2014 10 07 111...