background image

28

D 13887.08
MAY 2008

TANDBERG 3000 

MXP 

&

 

6000 

MXP

 REFERENCE GUIDE FOR SYSTEM INTEGRATORS

Interfaces and Sockets – Codec 3000 

MXP

Power cord socket. 

 

Accepts 12 V DC / 4.3 A

Power switch

CauTioN!

 

This equipment  

must be earthed!

Power Socket & On/Off Switch

Summary of Contents for Codec 3000 MXP

Page 1: ...PS FTP and on screen menu Best possible call for each MultiSite participant with rate matching and transcoding URI dialling H 323 H 320 SIP support TANDBERG Expressway Technology Protection against network interruptions in point to point and multipoint calls with automatic downspeeding and IPLR Standards based embedded encryption AES DES Software version F7 X D13887 08 MAY 2008 Codec MXP 3000 6000...

Page 2: ...ec 3000MXP and Codec 6000MXP have been designed to provide you with many years of safe reliable operation This section of the User Guides contains an overview of what s new in this version and the Table of Contents Our objective with this Reference User Guide for System Integrators has been to address your goals and needs Please let us know how well we succeeded Finding the Information You Need ...

Page 3: ... docu ment follow the link http www tandberg com support docu mentation php and select White Papers Kiosk OneClickConnect On Off New in this version If turned On you can make a call with a single click on the green call button on the remote control The system will call the first entry in My Contacts in the Phone Book NOTE This functionality will only work in Kiosk Mode If set to Off Does not allow...

Page 4: ...w in this version Enables disables the given key on the TANDBERG Remote Control Key Left On Off New in this version Enables disables the given key on the TANDBERG Remote Control Key Selfview On Off New in this version Enables disables the given key on the TANDBERG Remote Control Key Layout On Off New in this version Enables disables the given key on the TANDBERG Remote Control Key Phonebook On Off...

Page 5: ...isables the given key on the TANDBERG Remote Control TRC4 Key VCR On Off New in this version Enables disables the given key on the TANDBERG Remote Control TRC4 Key AUX On Off New in this version Enables disables the given key on the TANDBERG Remote Control TRC4 Command Instructions Observe that the r in the Command instructions denotes that the parameter is required The r appears for your informat...

Page 6: ... Video Sockets 23 Camera Socket 24 ISDN BRI sockets 25 Net socket 26 Network Interface Sockets 27 Power Socket On Off Switch 28 Interfaces and Sockets Codec 6000MXP Rear Panel Socket and Interface Groups 30 Audio Sockets 31 Audio Signal Levels in Vpp and dBu 32 Video Sockets 33 Net Interface Socket 34 Network Interface Sockets 35 Camera Sockets 36 Data Ports 37 Power Socket On Off Switch 38 About ...

Page 7: ...toPIP 70 Bonding 70 CallManager 70 CallVideoSource 71 Camera 71 CameraDVI 72 CameraSleep 72 CameraTracking 73 Conference 73 CorporateDirectory 77 DefaultPIPPosition 77 Directory 78 DoNotDisturb 78 DualMonitor 78 DuoVideoSource 78 DynamicResolution 78 E1 78 Ethernet 78 ExternalManager 78 ExternalNetwork 79 ExternalServices 79 FECC 80 FeedbackFilter 80 FTP 80 G703 80 H320 81 H323 81 H323CallSetup 81...

Page 8: ...rtualMonitorSet 164 Status Information Tables Understanding the Table Layout 166 Audio 167 BRI 168 Call 170 Camera 182 CameraSWUpgrade 183 CameraTracking 184 Conference 185 Ethernet 191 ExternalManager 192 ExternalNetwork 193 FarEndInformation 194 Feedback 196 G703 197 H323Gatekeeper 198 IP 199 NTP 200 PRI 201 RemoteSwUpgrade 204 Screensaver 205 SIP 206 SoftwareUpgrade 207 Switch 208 SystemUnit 21...

Page 9: ...s in connection with the use of the Products Except for the limited exception set forth in the previous sentence no part of this Reference Guide for System Integrators may be reproduced stored in a retrieval system or transmitted in any form or by any means electronically mechanically by photocopying or otherwise without the prior written permission of TANDBERG Requests for such permission should ...

Page 10: ...Guide for System Integrators however TANDBERG assumes no responsibility or liability for any errors or inaccuracies that may appear in this document INTELLECTUAL PROPERTY RIGHTS The Products that are covered by this Reference Guide for System Integrators are protected under copyright patent and other intellectual property rights of various jurisdictions Any applicable software licenses and any lim...

Page 11: ...l or some portions of this file are derived from material licensed to the University of California by American Telephone and Telegraph Co or Unix System Laboratories Inc and are reproduced herein with the permission of UNIX System Laboratories Inc Copyright 1995 1996 1997 and 1998 WIDE Project All rights reserved Copyright 2000 Brian Somers brian Awfulhak org Copyright 1998 The NetBSD Foundation I...

Page 12: ...r own protection please read the overleaf safety instructions completely before operating the equipment and keep this manual for future reference The information in this summary is intended for operators Carefully observe all warnings precautions and instructions both on the apparatus and in the operating instructions Operator Safety Environmental Issues ...

Page 13: ...d to the prod uct where this action requires a tool This product should always be powered from an earthed power outlet Never connect attached power supply cord to other products In case any parts of the product has visual damage never attempt to connect mains power or any other power source before consulting service personnel The plug connecting the power cord to the product power supply serves as...

Page 14: ...dfilled or incinerated TANDBERG has implemented necessary process changes to comply with the European RoHS Directive 2002 95 EC and the European WEEE Directive 2002 96 EC Waste Handling In order to avoid the dissemination of hazardous substances in our environment and to diminish the pressure on natural resources we encourage you to use the appropriate take back systems in your area Those systems ...

Page 15: ...D13887 08 MAY 2008 15 TANDBERG 3000MXP 6000MXP REFERENCE GUIDE FOR SYSTEM INTEGRATORS China RoHS Table Environmental Issues ...

Page 16: ...dberg com support documentation php What s in the Shipping Box This part of the Reference Guide for System Integrators presents the contents of the shipping box to ease your acceptance test as well as assist you in making sure you ve got everything with you if you need to take the codec along for installation etc ...

Page 17: ...entation Rack mounting kit I Rack mounting kit II Codec 3000 MXP User registration card Power supply Up to 4 mains cables depending on region 4 ISDN BRI cables not included with the NET version Video DVI VGA cable Split cable for non TANDBERG WAVE II cameras 1 LAN Ethernet cable What s in the Shipping Box Contents of the 3000MXP Codec Shipping Box ...

Page 18: ...nts of the 6000MXP Codec Shipping Box Remote control Batteries for remote control CD with user documentation Rack mounting kit I Rack mounting kit II Codec 6000 MXP User registration card 6 ISDN BRI cables 1 ISDN PRI cable 1 LAN Ethernet cable DVI VGA cable Up to 4 mains cables depending on region Mains extension cable ...

Page 19: ...ons of this manual http www tandberg com support documentation php Interfaces and Sockets Codec 3000MXP This part of the manual provides an in depth presentation of the rear panel sockets and interfaces of the Codec 3000MXP including the audio signal levels and the formats supported ...

Page 20: ...t and On Off switch Network interface sockets PC card Camera ISDN BRI Net socket Camera Audio sockets Video sockets DC power socket and On Off switch Network interface sockets PC card Codec 3000MXP Codec 3000MXP Net The Codec 3000 MXP comes in two flavours with ISDN BRI sockets upper or with Net socket lower Ethernet Ethernet Rear Panel Socket and Interface Groups ...

Page 21: ...l 83mVpp 15 5Vpp Max output level when set to max output level 15 5Vpp Max input level when set to max input level 6 2mVpp 1 2Vpp Max output level when set to min output level 1 2Vpp Gain range 22 5dB 16 steps of 1 5dB Phantom power 24V 5 Phantom power resistor pin 2 1200W Phantom power resistor pin 3 1200W Max phantom power current 12mA XLR pin out External view of socket Pin 1 Gnd Pin 2 Hot Pin ...

Page 22: ... 8 38 9 56 9 12 0 20 8 40 4 58 4 13 5 17 5 41 9 59 9 15 0 14 8 43 4 61 4 16 5 12 4 44 9 62 9 18 0 10 4 46 4 64 4 19 5 8 8 47 9 65 9 21 0 7 4 49 4 67 4 22 5 6 2 50 9 68 9 Audio Outputs 1 2 Signal levels Signal levels Absolute max output level Nominal level Input menu level setting dB Vpp dBu dBu 0 0 1 2 5 5 23 5 1 5 1 4 4 0 22 0 3 0 1 6 2 5 20 5 4 5 1 9 1 0 19 0 6 0 2 3 0 5 17 5 7 5 2 8 2 0 16 0 9 ...

Page 23: ...Note TANDBERG supports DVI D Single Link DVI A and DVI I Sin gle Link format cables DVI D cables transmit digital T M D S signals DVI A cables transmit analogue VGA signals and DVI I cables can transmit either digital or analogue signals If your DVI cable is not long enough use extension cables Observe however that the maximum cable length should not exceed 5m to avoid quality loss Formats support...

Page 24: ...S VIDEO DSUB 12V DC 8 4 GND 7 5 12V DC 3 4 TXD 4 3 RXD 5 2 GND 6 5 GND 2 5 12V DC 1 4 Y GND 1 8 C_GND 2 1 Y 3 9 C 4 6 NC 7 Split cable for non TANDBERG WAVE II cameras Non TANDBERG Camera cable pin out SIGNAL NAME DSUB Camera S VIDEO DSUB Codec 12V DC 1 4 GND 2 5 12V DC 3 4 TXD 4 3 RXD 5 2 GND 6 5 GND 7 5 12V DC 8 4 Y GND 1 8 C_GND 2 1 Y 3 9 C 4 6 NC 7 TANDBERG HD 3000 Camera cable pin out SIGNAL ...

Page 25: ...0 RJ 45 Jack Basic Rate Interface S T 2B D 128kbps per ISDN I F Use any standard BRI cable to connect the Codec to BRI S T Interface BRI Pin out Pin 3 TX Pin 4 RX Pin 5 RX Pin 6 TX ISDN BRI sockets not applicable to 3000 MXP Net Tip Wherever applicable the use of Category 5 cabling or better is strongly recommended For HD camera applications however Category 7 5 is required ...

Page 26: ...TE DCE Pin Signal name Direction Description 1 FGND Frame GND 11 T A Send Data Transmit 12 T B Send Data Transmit 13 R A Received Data Receive 14 R B Received Data Receive 15 S A Signal Element Timing 16 S B Signal Element Timing 20 C A Terminal Ready Control 21 C B Terminal Ready Control 22 I A Carrier Detect 23 I B Carrier Detect Net interface socket 1 X 21 V 35 RS449 with 1 RS366 Call Control u...

Page 27: ...tween the PC and the Codec make sure both static IP addresses exist on the same subnet Data port Pin Signal name Direction 1 Carrier detect CD From DCE 2 Receive data RXD From DCE 3 Transmit data TXD To DCE 4 Data terminal ready DTR From DCE 5 Signal GND 6 Data set ready DSR From DCE 7 Ready to send RTS To DCE 8 Clear to send CTS From DCE 9 Ring indicator RI From DCE Data port The Data port is imp...

Page 28: ...08 TANDBERG 3000MXP 6000MXP REFERENCE GUIDE FOR SYSTEM INTEGRATORS Interfaces and Sockets Codec 3000MXP Power cord socket Accepts 12V DC 4 3A Power switch Caution This equipment must be earthed Power Socket On Off Switch ...

Page 29: ...ons of this manual http www tandberg com support documentation php Interfaces and Sockets Codec 6000MXP This part of the manual provides an in depth presentation of the rear panel sockets and interfaces of the Codec 6000MXP including the audio signal levels and the formats supported ...

Page 30: ...ets Codec 6000MXP D13887 08 MAY 2008 TANDBERG 3000MXP 6000MXP REFERENCE GUIDE FOR SYSTEM INTEGRATORS Audio sockets Video sockets Rear Panel Socket and Interface Groups Network interface sockets Power socket and On Off switch ...

Page 31: ...formation For systems configured with stereo I O stereo speakers and SPDIF not active this output will provide the mix of left and right channel of the VCR out signal XLR pin out External view of socket Pin 1 Gnd Pin 2 Hot Pin 3 Cold neutral 1 2 3 Use Audio Output No 1 to provide a mixed signal of audio from far end and local external devices connected to input 5 6 in addition to dial tones This o...

Page 32: ...signal levels Signal levels Clipping levels Nominal level Input menu level setting dB Vpp dBu dBu 0 0 15 5 17 0 1 0 1 5 13 0 15 5 2 5 3 0 11 0 14 0 4 0 4 5 9 2 12 5 5 5 6 0 7 8 11 0 7 0 7 5 6 5 9 5 8 5 9 0 5 5 8 0 10 0 10 5 4 6 6 5 11 5 12 0 3 9 5 0 13 0 13 5 3 3 3 5 14 5 15 0 2 8 2 0 16 0 16 5 2 3 0 5 17 5 18 0 2 0 1 0 19 0 19 5 1 6 2 5 20 5 21 0 1 4 4 0 22 0 22 5 1 2 5 5 23 5 This specification ...

Page 33: ...VGA 800 600 75Hz XGA 1024 768 60Hz SXGA 1280 1024 60Hz HD720p 1280 720 50Hz 60Hz WXGA 1280 768 60Hz Formats supported on DVI I in SVGA 800 600 60Hz 72Hz 75Hz 85Hz XGA 1024 768 60Hz 70Hz 75Hz SXGA 1280 1024 60Hz HD720p 1280 720 50Hz 60Hz Levels Composite 1Vpp 75W S Video Y C Y 1Vpp 75W C PAL 0 3Vpp 75W C NTSC 0 28Vpp 75W Do as follows to get WXGA 1 VGA Out Quality must be set to Auto 2 VGA Monitor ...

Page 34: ... Receiver Ready 23 RR B Carrier Detect Receiver Ready 24 IC Incoming Call 25 LOS Loss of Signal KG194 Frame GND is connected to pin 1 on DTE 1 This pin is connected to ground for correct operations Note the following V 10 RS423 For balanced signals a 0 low voltage is defined as terminal A positive with respect to terminal B For unbalanced signals a 0 low voltage is defined as terminal positive wit...

Page 35: ...ck interface 10 100Mb Up to 4 or 6Mbps depending on the bandwidth op tion installed Use any standard Ethernet cable to connect the Codec to a LAN If no LAN is available and the Codec is connected directly to a computer use a crossover cable Ethernet cable 1 1 2 2 3 3 6 6 1 1 2 2 3 3 6 6 Wiring diagram standard cable Wiring diagram crossover cable RJ 45 Connector pin out E1 T1 Interface PRI Pin Out...

Page 36: ... NAME RJ 45 DSUB 12V DC 8 4 GND 7 5 12V DC 3 4 TXD 4 3 RXD 5 2 GND 6 5 GND 2 5 12V DC 1 4 TANDBERG HD 6000 Camera cable pin out SIGNAL NAME RJ 45 DSUB 12V DC 1 Twisted pair 4 GND 2 5 Rx 3 Twisted pair 2 TX 6 3 LVDS 4 Twisted pair 1 LVDS 5 6 GND 7 Twisted pair 5 12V DC 8 4 RJ 45 Connector pin out Cable is Category 7 5 Class F AWG24 Extreme care should be taken if you choose to make your own version...

Page 37: ...DCE Data set ready DSR From DCE 7 Ready to send RTS To DCE Ready to send RTS To DCE 8 Clear to send CTS From DCE Clear to send CTS From DCE 9 Ring indicator RI From DCE Ring indicator RI From DCE 1 The TANDBERG main camera is normally connected to data port 2 and pin No 4 provides 12Vdc 1A to the main camera Otherwise the pin outs are the same for the two data ports Data port 1 upper and 2 lower T...

Page 38: ...DBERG 3000MXP 6000MXP REFERENCE GUIDE FOR SYSTEM INTEGRATORS Interfaces and Sockets Codec 6000MXP Power Socket On Off Switch Power cord socket Accepts 100 240V 50 60Hz 1A max Power switch Caution This equipment must be earthed ...

Page 39: ...he TANDBERG API The heart of the API is the TANDBERG API Engine This is where all information is stored and processed The API engine can be accessed by an easy to use Command Line Interface called XACLI using RS232 or Telnet or by the TANDBERG XML API Service TXAS over HTTP HTTPS Both alternatives are described in detail in this section of the User Guide ...

Page 40: ...d by the system Typical examples include status about ongoing calls network status confer ence status etc All status information is structured in a hierarchy making up a database con stantly being updated by the system to reflect process changes W Write information This is Command Information the user control applica tion supply to initiate an action Typical examples include instructing the system...

Page 41: ...udRate Example xconfiguration serialport 2 baudrate c xConfiguration SerialPort 2 BaudRate 9600 OK About the TANDBERG API The TANDBERG MXP also supports the RS232 Telnet Da taport Interface that was supported on the Classic systems You may use any mixture of Classic Dataport commands and XACLI commands on the same RS232 Telnet session A multitude of the commands overlaps but XACLI offers more flex...

Page 42: ...ion NOTE A straight through cable should be used between the TANDBERG MXP s RS232 port and the DTE The lower table shows the recommended cable wiring scheme when connecting the TANDBERG MXP to a PC through RS232 DTR and RTS are ignored DSR CD and CTS are always as serted while RI is not used Connecting to XACLI using the Dataport RS232 Hardware Cabling RS232 Pin Signal name Direction 1 Carrier det...

Page 43: ...all h323status pldownspeed vidtone defvalues h331mode preset activate vnc delbox help preset list vol dial ifconfig preset store websnapshots directory ipaddress pressource xcommand disable ipassignment pricable xconfiguration disc ipconflictcheck pricrc4 xdirectory dispbox iplr prihighch xevent dispparam ippassword prilowch xfeedback disptxt irctrl primaxchan xgetxml dltxt isdntrace prinsf xhisto...

Page 44: ...m the TANDBERG MXP very simple More on this can be found in xpreferences xgetxml gives access to the exact same information as the Main types of commands xstatus xhistory xconfiguration etc but returns the information XML formatted More on this can be found in xgetxml Commands returning information about the system and system processes i e information generated by the system E g status about ongoi...

Page 45: ...RG API Example xconfiguration User Configurations AdditionalCamera FTP OSD AlertSpeaker G703 PacketlossDownSpeed AlertTone H320 PictureProgram 1 4 Audio H323 PresentationStart AutoAnswer H323CallSetup Preset 1 15 AutoDisplaySnapshot H323Gatekeeper QoS AutoLayout H323Prefix RemoteSwUpgrade AutoPIP HTTP RTP Bonding HTTPS Screensaver CallManager IdReport SelfViewOnStartup Camera 1 13 IEEE802 1x Seria...

Page 46: ...y Manual Auto OK To read configurations from the system just type the root command xConfiguration xDirectory followed by the path address expression configuration type command address expression Example xconfiguration h323gatekeeper discovery c xConfiguration H323Gatekeeper Discovery Manual OK Type a root command xConfiguration xDirectory followed by a valid path address expression The path must b...

Page 47: ... that the input must be an IPv4 address IPAddr IPv6 Address values IPv6Addr x y Defines that the input must be an IPv6 address with minimum length x and maximum length y IPv6Addr 0 43 IPv4 or IPv6 Address values IPv4v6Addr x y Defines that the input must be an IPv4 or IPv6 address with minimum length x and maximum length y IPv4v6Addr 0 43 XACLI Configuration Types About the TANDBERG API The system...

Page 48: ...ceDisconnect FloorToSite SStringSend ConferenceTerminate FloorToSiteEnd StillImageSend CorpDirGetNext GroupEntryAdd StreamingStart CorpDirGetPrevious GroupEntryDelete StreamingStop CorpDirSearch KeyDisable TextDelete DefaultValuesSet KeyEnable TextDisplay Dial KeyPress VirtualMonitorReset DialGlobalEntry KeyRelease VirtualMonitorSet DialGroupEntry LocalEntryAdd OK Note The list provided here appea...

Page 49: ... after the tag separated with a dot command type command command parameter item value parameter item value Example xcommand groupentryadd name TANDBERG localentryid 1 15 localentryid 2 57 Issuing a Command Command Response Sequence Notation Optional command type root command command value value When using this notation the parameter values must be entered in the sequence as stated in the help text...

Page 50: ...0 Literal values X Y Z Defines the possible values for a given configuration On Off Auto String values S x y Defines that the valid input for this configuration is a String with minimum length x and maximum length of y characters S 0 49 IPv4 Address values IPAddr Defines that the input must be an IPv4 address IPAddr IPv6 Address values IPv6Addr x y Defines that the input must be an IPv6 address wi...

Page 51: ... API About Status Type Commands All Status information is organized in a hierarchic tree structure very much like files and folders on a computer The tree structure consists of container elements folders and value elements files Container elements contains sub elements while value elements contain values All elements have an element name and an element item number There can exist multiple instance...

Page 52: ...n CIF Rate 704 Video 2 status Inactive Data status Inactive Channels 2 type Outgoing Rate 768 Restrict Off Encryption status Off Audio status Active Protocol G722 Rate 64 Video 1 status Active Protocol H264 Resolution CIF Rate 704 Video 2 status Inactive Data status Inactive s end From the example showing status for a disconnected call upper right we can see that the call element now only contains...

Page 53: ...2 Audio Rate 64 s Call 1 Channels 2 Video 1 status Active s Call 1 Channels 2 Video 1 Protocol H264 s Call 1 Channels 2 Video 1 Resolution CIF s Call 1 Channels 2 Video 1 Rate 704 s Call 1 Channels 2 Video 2 status Inactive s Call 1 Channels 2 Data status Inactive s end OK The following should be observed Complete Path formatting is recommended for easy parsing All lines are prefixed with s for st...

Page 54: ...Off Restrict Encryption item 1 status Off Audio item 1 status Active Protocol item 1 G722 Protocol Rate item 1 64 Rate Audio Video item 1 status Active Protocol item 1 H264 Protocol Resolution item 1 CIF Resolution Rate item 1 704 Rate Video Video item 2 status Inactive Data item 1 status Inactive Channels Channels item 2 type Outgoing Rate item 1 768 Rate Restrict item 1 Off Restrict Encryption i...

Page 55: ...ng logTag 3 CallRate 768 s end OK Example 1 b xpreferences completepath set to on xstatus call 1 callrate s Call 1 status Synced type Vtlph protocol H323 direction Outgoing logTag 3 s Call 1 CallRate 768 OK Example 2 a the user wants to know Audio status for both incoming and outgoing channels for Call 1 xstatus call 1 channels audio s Call 1 status Synced type Vtlph protocol H323 direction Outgoi...

Page 56: ...col G722 Rate 64 Video 1 status Active Protocol H264 Resolution CIF Rate 704 Video 2 status Inactive Data status Inactive Channels 2 type Outgoing Rate 768 Restrict Off Encryption status Off Audio status Active Protocol G722 Rate 64 Video 1 status Active Protocol H264 Resolution CIF Rate 704 Video 2 status Inactive Data status Inactive s end OK Request for Call 1 element with exposure option xstat...

Page 57: ...or xfeedback deregister index or xfeedback list note deregistration with index 0 will deregister all registered expressions OK Example User wants to monitor all changes to the Call sta tus elements the Conference status element and all Configurations xfeedback register status call OK xfeedback register status conference OK xfeedback register configuration OK Example To list the registered expressi...

Page 58: ...e when feedback is issued see below xstatus call 1 s Call 1 status Synced type Vtlph protocol H323 direction Outgoing logTag 30 CallRate 768 RemoteNumber 558458 Mute Off Microphone Off Duration 62 MuteOutgoing Off Channels 1 type Incoming Rate 768 Restrict Off Encryption status On Type AES 128 CheckCode C6D478F231E09A04 Audio status Active Protocol G722 Rate 64 Video 1 status Active Protocol H264 ...

Page 59: ... path to the configurations to be set no double slashes allowed This will improve the performance of the system when issu ing many consecutive configurations NOTE It is always recommended to supply the complete path for configurations to be set when issuing commands from an external control application xpreferences detaillevel xpreferences detaillevel 1 2 Most information elements accessible by th...

Page 60: ...ent item number However XACLI hides the item number for an element if there only exist one item of the given element If xpreferences itemnumber is set to on XACLI will display item numbers for all elements This is to make it easier to parse the information sent from the codec By setting xpreferences itemnumber on the parser can always expect an item number to follow an element name Example Reading...

Page 61: ...ctive Data status Inactive s end OK Example Reading status for Call 1 with xpreferences completepath on xstatus call 1 s Call 1 status Synced type Vtlph protocol H323 direction Outgoing logTag 2 s Call 1 CallRate 768 s Call 1 RemoteNumber 558458 s Call 1 Mute Off s Call 1 Microphone Off s Call 1 Duration 527 s Call 1 MuteOutgoing Off s Call 1 Channels 1 type Incoming s Call 1 Channels 1 Rate 768 s...

Page 62: ...s item 1 10 47 11 179 Address SubnetMask item 1 255 255 248 0 SubnetMask Gateway item 1 10 47 8 1 Gateway V6 item 1 Address item 1 type NA Address Address item 2 type NA Address V6 DNS item 1 Server item 1 Address item 1 10 0 0 10 Address Server Server item 2 Address item 1 10 0 0 2 Address Server Server item 3 Address item 1 Address Server Server item 4 Address item 1 Address Server Server item 5...

Page 63: ...l PARAM location XPath expression getxml request returns an XML document based on the location parameter passed to the request The elements or complete document matching the expression will be returned On Incorrect XPath expression a Fault element with a XPathError element will be re turned formputxml REQUEST formputxml PARAM xmldoc an XML document of Configuration Directory or Command This is mos...

Page 64: ...p www tandberg com support documentation php This part of the manual describes the Configuration information available There are two types of configuration type commands available xconfiguration configuration xml xdirectory directory xml Both types are covered in this section Configuration type Commands ...

Page 65: ... alert tone to use for incoming video telephony calls Example xconfiguration alerttone videotelephony 10 AlertTone Telephony 1 10 Defines the alert tone to use for incoming telephony calls Example xconfiguration alerttone telephony 8 AllowLatency On Off If set to Off default the IP call rate will sometimes exceed the maximum callrate specified for the call to reduce latency In some cases with poor net...

Page 66: ... recommend the use of different alert tones for video calls and telephone calls AlertTone VideoTelephony 1 10 Defines the alert tone to use for incoming video telephony calls Example xconfiguration alerttone videotelephony 10 AlertTone Telephony 1 10 Defines the alert tone to use for incoming telephony calls Example xconfiguration alerttone telephony 8 AllowLatency On Off If set to Off default the...

Page 67: ... is also connected to this AGC Example xconfiguration audio agc microphones on Audio AGC AUX On Off Turns the AGC connected to the AUX input On or Off NOTE The AUX input is also sometimes referred to as Line Input 2 or AUX Audio in 5 6000MXP and Line Input 1 or Audio In 3 3000 MXP Example xconfiguration audio agc aux on Audio AGC VCR On Off Turns the AGC connected to the VCR input On or Off NOTE O...

Page 68: ... at the far end Example xconfiguration audio vcrducking on Audio KeyTones On Off If set to On there will be a sound indicator when pressing keys on the remote control Example xconfiguration audio keytones on Audio Inputs Microphone 1 x 6000MXP x 3 3000MXP x 2 Level 1 16 Defines the input levels for the different microphones Example xconfiguration audio inputs microphone 2 level 10 By default all i...

Page 69: ...le xconfiguration audio outputs line 2 mode off Audio Outputs Line 1 6000MXP x 3 3000MXP x 2 Type Analog SPDIF Auto Note Applies to Line 1 only This configuration is also referred to as Out 1 Mode If Out 1 Mode is set to Auto the system will select analogue or digital SPDIF mode depending on the detected Audio Module If a TANDBERG Digital NAM is detected SPDIF mode will be selected otherwise analo...

Page 70: ...no automatic change of the local pictrure layout during the conference All desired layout changes must be done manually ref LocalLayout Example xconfiguration autolayout mode off AutoPIP Mode On Off Auto This configuration only applies if LocalLayout Toggle is set to PIP If set to On the system will display a PIP containing the farend mainstream when dual video stream is activated If set to Auto t...

Page 71: ...anual Auto If set to Auto the camera will continuously adjust the whitebalance depending on the camera view When set to Manual the whitebalance can be calibrated manually by the command CameraWhiteBalance The white balance of the camera will then remain constant until a new calibration is performed Example xconfiguration camera 1 whitebalance mode auto Camera 1 13 Whitebalance Level 0 16 Specifies...

Page 72: ...in If that s the case control of the 2nd PrecisionHD camera is automatic when the PC Input is selected If you have any other type of camera with a VGA DVI HDMI output you must put it last in the chain and manually turn this configuration On When you select the PC Input you will gain control of the last camera This configuration may be useful when using the VGA output on a Sony BRC H700 camera Impo...

Page 73: ...than the default unrestricted 64kbps channels Some older networks primarily in the USA do not support 64kbps channels and require the use of restricted 56kbps calls By default the system will dial an unrestricted call and downspeed to 56kbps if necessary To force a restricted call choose Restrict 56k On Example xconfiguration conference defaultcall restrict off Conference DefaultCall NetProfile 1 ...

Page 74: ...uration conference h264rcdo off Conference G722 On Off Enables disables G 722 for both transmit and receive Example xconfiguration conference g722 on Conference G722 1 On Off Enables disables G 722 1 for both transmit and receive Example xconfiguration conference g722 1 on Conference G728 On Off Enables disables G 728 for both transmit and receive Example xconfiguration conference g728 on Conferen...

Page 75: ...deo can also be configured to be enabled for callrates above a specified threshold value Example xconfiguration conference naturalvideo 768 This will enable NaturalVideo for callrate 768 kbps and above Conference PictureMode 4Split 5 1Split VS Auto Sets the picture layout to be used in a MultiSite conference If set to Auto the system will change the picture layout depending on the number of partic...

Page 76: ...iated If set to DES the system will always try to set up the call using DES with 56 bits encryption on ISDN and IP If all other sites do not support DES no other type of encryption will be initiated Example xconfiguration conference encryption type AES 128 Conference AIM On Off Enables disables Auto Indicate Mute If disabled the system will not signal to the other side that the microphone is turne...

Page 77: ... names for a period of time or as long as you are connected Example xconfiguration conference videotext on Conference VideoTextTimeout 0 30 Sets the timer for the On screen name of participants in MultiSite calls Set the timer to display the names for a period of time or as long as you are connected Requires the VideoText setting to be enabled Example xconfiguration conference videotext 0 Corporat...

Page 78: ...on it is in the picture The call will start with 720p and change to a lower resolution when there is a lot motion It will go back to 720p with less motion If set to Off Disables the Dynamic Resolution feature the default setting Example xconfiguration dynamicresolution mode off E1 Interface CRC4 On Off E1 CRC 4 is used for most E1 PRI configurations You can turn it off if not supported by the E1 n...

Page 79: ...able for the following bandwidths kbps 64 64 Restrict 128 128 Restrict 192 192 Restrict 256 256 Restrict 320 320 Restrict 384 384 Restrict 512 512 Restrict 768 768 Restrict 1152 1152 Restrict 1472 1472 Restrict 1920 1920 Restrict LeasedLine Leased Line is a non dialling protocol and should be used when two codecs are connected in a point to point connection Use Leased Line when the handshaking sig...

Page 80: ...dback filter in seconds for the Call status element Example xconfiguration feedbackfilter call 2 FTP Mode On Off Enables or disables the systems embedded FTP server Example xconfiguration ftp mode on G703 PhysicalLayer E1 T1 Selects whether the leased line is E1 or T1 Example xconfiguration g703 physicallayer e1 G703 Linecoding b8zsRestrict b8zsNoRestrict Selects whether the Leased line is a 56kb ...

Page 81: ...e H323CallSetup Mode is set to Gatekeeper or Callmanager Example xConfiguration h323callsetup mode gatekeeper H323Gatekeeper Discovery Manual Auto Auto The system will automatically try to register to any available gatekeeper If a gatekeeper responds to the request sent from the codec within 30 seconds this specific gate keeper will be used This requires auto discovery on the gatekeeper as well If...

Page 82: ...le xconfiguration h323gatekeeper avaya password 123 H323Gatekeeper MultipleAlias On Off If set to On the system will register multiple H 323 IDs on the Gatekeeper based on the values of the parameters System Name International Name and H 323 ID Up to 3 aliases are possible If set to Off the system will register a single H 323 IDs on the Gatekeeper based on the following priority H 323 ID 1 Interna...

Page 83: ...mple xconfiguration http mode on HTTPS Mode On Off Enables disables HTTPS Example xconfiguration https mode on HTTPS VerifyServerCertificate On Off TANDBERG MXP systems now support secure management when communicating with the TMS For more information see the TANDBERG White Paper Implementing Secure Management which describes how to configure secure HTTPS between TANDBERG products To find the docu...

Page 84: ...e802 1 x identity MyString IEEE802 1x Password S 0 64 The 802 1x Password is the password needed for 802 1x authentication Example xconfiguration ieee802 1x password MyPassword IEEE802 1x EAP MD5 On Off Enables disables the EAP MD5 protocol Example xconfiguration ieee802 1 x eap md5 on IEEE802 1x EAP TTLS On Off Enables disables the EAP TTLS protocol Example xconfiguration ieee802 1 x eap ttls on ...

Page 85: ...xx IMUX Custom BW128R Suffix S 0 12 Defines the suffix to be used with the RS366 Custom IMUX at this restricted bandwidth Example xconfiguration imux custom bw128r suffix xxx IMUX Custom BW192 Prefix S 0 12 Defines the prefix to be used with the RS366 Custom IMUX at this bandwidth Example xconfiguration imux custom bw192 prefix xxx IMUX Custom BW192 Suffix S 0 12 Defines the suffix to be used with...

Page 86: ...xxx IMUX Custom BW320 Suffix S 0 12 Defines the suffix to be used with the RS366 Custom IMUX at this bandwidth Example xconfiguration imux custom bw320 suffix xxx IMUX Custom BW320R Prefix S 0 12 Defines the prefix to be used with the RS366 Custom IMUX at this restricted bandwidth Example xconfiguration imux custom bw320r prefix xxx IMUX Custom BW320R Suffix S 0 12 Defines the suffix to be used wi...

Page 87: ...xx IMUX Custom BW512R Suffix S 0 12 Defines the suffix to be used with the RS366 Custom IMUX at this restricted bandwidth Example xconfiguration imux custom bw512r suffix xxx IMUX Custom BW768 Prefix S 0 12 Defines the prefix to be used with the RS366 Custom IMUX at this bandwidth Example xconfiguration imux custom bw768 prefix xxx IMUX Custom BW768 Suffix S 0 12 Defines the suffix to be used with...

Page 88: ...x IMUX Custom BW1472 Suffix S 0 12 Defines the suffix to be used with the RS366 Custom IMUX at this bandwidth Example xconfiguration imux custom bw1472 suffix xxx IMUX Custom BW1472R Prefix S 0 12 Defines the prefix to be used with the RS366 Custom IMUX at this restricted bandwidth Example xconfiguration imux custom bw1472r prefix xxx IMUX Custom BW1472R Suffix S 0 12 Defines the suffix to be used...

Page 89: ...c IP assignment NOTE This configuration only applies to IPv4 Example xconfiguration ip assignment dhcp IP Address IPAddr Defines the IPv4 address to use Only applicable if Static IP assignment is being used Example xconfiguration ip address IP SubnetMask IPAddr Defines the subnet mask Only applicable if Static IP assignment is being used Example xconfiguration ip subnetmask IP V6 Address IPv6Addr ...

Page 90: ...N CliNumbSpec On Off Explicitely specify Calling Party Number fields Type Plan to be used in outgoing calls in the ISDN setup message Using default values if set to Off When set to on the system will use the values set by ISDN ClinNumPlan and ISDN ClinNumbType Example xConfiguration isdn clinumbspec Off ISDN CliNumbType 0 6 Value to be used for Calling Party Number field Type If the value is set t...

Page 91: ... T310 T304 T301 Example xconfiguration isdn speechtimers on ISDN MSN On Off The use of MSN Multiple Subscriber Number enables you to attach different ISDN terminals with different numbers to the same physical ISDN telephone line If MSN is set to On only calls to numbers specified for the specific ISDN interfaces will be answered This service can be ordered from your telephone company Example xconf...

Page 92: ...ony mode on ISDN PRI NSFVideoTelephony Number 0 31 Defines what Service Facility to use for videotelephony if NSFVideoTelephony Mode is set to On Example xconfiguration isdn pri nsfvideotelephony number 8 ISDN PRI SwitchType NI ATT Euro Japan Selects the type of PRI switch the system is connected to Example xconfiguration isdn pri switchtype ni ISDN PRI InitialRestart On Off When restart is set to...

Page 93: ...h Low Selects whether to start searching for available B channels from the highest numbered channel or from the lowest numbered channel Example xconfiguration isdn pri interface search high ISDN PRI Interface NumberRangeStart S 0 24 Defines the number range start supported by the PRI interface Example xconfiguration isdn pri interface numberrangestart 1 ISDN PRI Interface NumberRangeStop S 0 24 De...

Page 94: ...om the lowest numbered interface Example xconfiguration isdn bri interfacesearch high ISDN BRI Interface 1 6 Mode On Off Enables disables the various BRI interfaces Example xconfiguration isdn bri interface 4 mode off ISDN BRI Interface 1 6 DirectoryNumber 1 2 S 0 24 Specifies the Directory Numbers for the various BRI interfaces Example xconfiguration isdn bri interface 4 directorynumber 2 6623 IS...

Page 95: ...umber5 on Key Number6 On Off Enable or disable the given key on the TANDBERG Remote Control and using configuration instead of commands Example xconfiguration key number6 on Key Number7 On Off Enable or disable the given key on the TANDBERG Remote Control and using configuration instead of commands Example xconfiguration key number7 on Key Number8 On Off Enable or disable the given key on the TAND...

Page 96: ...n Key Right On Off Enable or disable the given key arrow right on the TANDBERG Remote Control and using configuration instead of commands Example xconfiguration key right on Key Left On Off Enable or disable the given key arrow left on the TANDBERG Remote Control and using configuration instead of commands Example xconfiguration key left on Key Selfview On Off Enable or disable the given key Selfv...

Page 97: ...guration key volumedown on Key Ok On Off Enable or disable the given key OK Menu key on the TANDBERG Remote Control and using configuration instead of commands Example xconfiguration key ok on Key ZoomIn On Off Enable or disable the given key Zoom on the TANDBERG Remote Control and using configuration instead of commands Example xconfiguration key zoomin on Key ZoomOut On Off Enable or disable the...

Page 98: ...tead of commands Example xconfiguration key maincam on Key PC On Off Enable or disable the given key on the TANDBERG Remote Control TRC4 and using configuration instead of commands Example xconfiguration key pc on Key DocCam On Off Enable or disable the given key on the TANDBERG Remote Control TRC4 and using configuration instead of commands Example xconfiguration key doccam on Key VCR On Off Enab...

Page 99: ...enu Swedish On Off Enables On or diables Off language menu in Swedish Example xconfiguration kiosk languagemenu swedish on Kiosk LanguageMenu Spanish On Off Enables On or diables Off language menu in Spanish Example xconfiguration kiosk languagemenu spanish on Kiosk AllowIRControl On Off Enables On or diables Off the use of all keys on the remote control Example xconfiguration kiosk allowircontrol...

Page 100: ... to POP the system will toggle through the different LocalLayout modes when pressing the Layout button If set to PIP the system will display a PIP when pressing the Layout button Example xconfiguration locallayout toggle pip Logo On Off If set to On the system will display a company logo will appear in the background of the welcome menu NOTE The TANDBERG logo will be displayed if no other company ...

Page 101: ...ultiSite On Off Specify if the optional feature MultiSite should be enabled disabled Example xconfiguration multisite on MCU MultiWay On Off Specify if the optional feature MultiWay should be enabled disabled Example xconfiguration multiway on NAT Mode On Off Auto When set to On the system will signal the configured NAT Address in place of its own IP address within Q 931 and H 245 When set to Off ...

Page 102: ...f no DHCP server is used or the DHCP server does not provide the system with a NTP server address the system will use the static defined NTP server address specified by the user If set to Manual the system will always use the static defined NTP server address specified by the user Example xconfiguration ntp mode manual The Network Time Protocol NTP is used to synchronize the time of the system to ...

Page 103: ...ns the Main Menu System Status System Name and Dial in numbers If set to On the Welcome Menu is shown when the system wakes up from standby mode If set to Off the Welcome Menu is not shown when the system wakes up from standby mode However pressing the OK button on the remote control will display the Welcome Menu Example xconfiguration osd menu welcomemenu on OSD Menu DisplayWelcomeText On Off If ...

Page 104: ...ncryption Bad Network Telephone Duo Video and Camera Tracking Places the icons in the top left corner or the top right corner of the screen Example xconfiguration osd menu iconplacement right OSD Icon MicOff On Off Enables Disables the Microphone Off icon Example xconfiguration osd icon micoff on OSD Icon VolumeOff On Off Enables Disables the Volume Off icon Example xconfiguration osd icon volumeo...

Page 105: ...Full 2Split 4Split 2 1Split 3 1Split 5 1Split Example xconfiguration pictureprogram 1 layout full The Picture Programs are used to define custom picture layouts to be displayed locally PictureProgram 1 4 Window 1 6 Picture LocalMain LocalDuo Current Previous Duo RemoteMain RemoteDuo JPEG TandbergMonitor1 TandbergMoni tor2 None Example xconfiguration pictureprogram 1 window 2 picture localmain Pict...

Page 106: ... Mode On Off Example xconfiguration preset 1 audio inputs mi crophone 2 on Preset 1 15 Audio Inputs Line 1 3 Mode On Off Example xconfiguration preset 1 audio inputs line 2 on Preset 1 15 MainVideoSource 1 2 3 4 5 6 Example xconfiguration preset 1 mainvideosource 1 Preset 1 15 DuoVideoSource 0 1 2 3 4 5 6 Example xconfiguration preset 1 duovideosource 1 Preset 1 15 SwitchVideoSource 0 1 2 3 4 5 6 ...

Page 107: ...turned on for 5 seconds If disabled the preset s focus value will be used Default is Off Example xconfiguration preset 1 camera autofocus off Preset 1 15 Camera Focus 0 65534 Interpretation of the settings chosen will depend on the camera type you use If in doubt consult your camera s user documentation Example xconfiguration preset 1 camera focus 32768 Preset 1 15 Camera Pan 32768 32766 Interpret...

Page 108: ...d to set priority on QoS enabled IP networks QoS Precedence Telephony Signalling 0 1 2 3 4 5 6 7 Auto Off Example xconfiguration qos precedence telephony signalling auto QoS Precedence VideoTelephony Audio 0 1 2 3 4 5 6 7 Auto Off Example xconfiguration qos precedence videotelephony audio auto QoS Precedence VideoTelephony Signalling 0 1 2 3 4 5 6 7 Auto Off Example xconfiguration qos precedence v...

Page 109: ...phony Signalling 0 63 Example xconfiguration qos diffserv telephony signalling 25 QoS DiffServ VideoTelephony Audio 0 63 Example xconfiguration qos diffserv videotelephony audio 15 QoS DiffServ VideoTelephony Signalling 0 63 Example xconfiguration qos diffserv videotelephony signalling 15 QoS DiffServ VideoTelephony Video 0 63 Example xconfiguration qos diffserv videotelephony video 15 QoS DiffSer...

Page 110: ...e number of bytes of video payload per packet Example xconfiguration rtp mtu 1200 Screensaver Mode On Off Enables disables if screensaver is to be activated if there is no system activity Example xconfiguration screensaver mode on Screensaver Delay 1 480 Specifies how long in minutes the system shall wait before activating screensaver when there is now system activity Example xconfiguration screen...

Page 111: ...2 Specify the number of stopbits on a Serial Port Example xconfiguration serialport 1 stopbits 2 SIP Mode On Off On Setting the SIP mode to on will enable the system for incoming and outgoing SIP calls Off Setting the SIP mode to off will disable incoming and outgoing SIP calls from the system Example xconfiguration sip mode on SIP ReplyTo URI S 0 60 If configured it is this URI that will be displ...

Page 112: ... Password S 0 60 This is the password part of the credentials used to authenticate towards the SIP Server Example xconfiguration sip authentication password SIP Transport Default Auto TCP UDP TLS Select the default transport type to be used for SIP signalling Example xconfiguration sip transport default tcp SIP TLS Verify On Off For TLS connections a CA list can be uploaded from the web interface ...

Page 113: ...deo source the system will use as default after a reboot and after the system goes out from screensaver mode If set to 0 the system will use the video source that was selected before reboot Example xconfiguration startupvideosource 1 StillImageSource 0 1 2 3 4 5 6 Defines the default still image source If set to 0 the system will use the current main video source as still image source Example xcon...

Page 114: ...the codec to stream to This address could be a multicast address broadcast address or a unicast address Example xconfiguration streaming address Streaming VideoRate 16 32 64 128 192 256 320 Selects the video rate in kbps to stream out on the network Example xconfiguration streaming videorate 128 Streaming Announcements On Off Turn On or Off Streaming Announcement Protocol Example xconfiguration st...

Page 115: ...tion secondary on Switch LogicalInput 1 5 1 MainCam 2 AUX 3 Doc Cam 4 VCR 5 PC Mode On Off Logical inputs are used when accessing inputs from the menu remote control and FECC There are five input buttons on the top of the TRC4 remote control and these can be remapped to any switch input you wish The same five buttons are visible in the Presentation Main Video menu and these will be remapped in the...

Page 116: ... ip port 23 or ip port 57 When connecting to an ip port that has telnetChallenge set to On an MD5 encryption challenge string are being issued instead of a password prompt An encrypted password based on the challenge string must then be generated by an MD5 encryptor and sent back to the system as a response in order to get access to the system NOTE Regular Telnet are using ip port 23 When TelnetCh...

Page 117: ...ain monitor is used as a local PC display UseAsLocalPCMonitor should be set to On This will avoid transmitting the local PC image while the system is in a video conference Example xconfiguration useaslocalpcmonitor on Video Inputs Source 5 HorizAdjust 0 255 NOTE Only Video Input Source 5 Gives you the possibility to adjust the placement of the pc image on screen Much like the setting you find on a...

Page 118: ... is higher than or equal to x kbps iSIF from NTSC if Natural Video is x kbps and the bit rate is higher than or equal to x kbps w448p will be used from a wide format HD720p input VGA SVGA XGA from PC Digital Clarity Sharpness Improved quality of detailed images and graphics 4xCIF will be used from a PAL video input Digital Clarity 4xSIF will be used from a NTSC video input Digital Clarity w720p wi...

Page 119: ...e format refresh rate and of the EDID information available Example xconfiguration video outputs dviresolution 1 auto Supported formats SVGA 800x600 75Hz XGA 1024x768 60Hz 75Hz WXGA 1280x768 60Hz SVGA VGA output format is forced to SVGA format 800x600 75Hz XGA VGA output format is forced to XGA format 1024x768 60Hz VGA Out Quality for Wide XGA If ScreenFormatPC is set to Wide FormatPCWi deScreen i...

Page 120: ...re not in use by default TV output 1 shows by default Virtual Monitor 1 Main Monitor while TV output 2 shows by default Virtual Monitor 2 Second Monitor To make TV output 2 also show Virtual Monitor 1 Example xconfiguration video outputs tv 1 virtualmonitor 1 Video Outputs TV 1 2 OSD On Off Specifies whether or not to display On Screen Display on the supported TV outputs Example xconfiguration vid...

Page 121: ...turn off video all unused video outputs Example xconfiguration video outputs DVI 1 Mode On VNC IPAddress S 0 64 Defines the IP address of the VNC server Example xconfiguration vnc ipaddress 10 47 15 49 VNC DisplayNumber S 0 5 The displaynumber of the VNC service This number must matcht the displaynumber of the VNC server Example xconfiguration vnc displaynumber 2 VNC Password S 0 8 Defines the pas...

Page 122: ...se Restrict when calling this entry A restricted call uses 56kbps channels rather than the default unrestricted 64kbps channels Some older networks primarily in the USA do not support 64kbps channels and require the use of restricted 56kbps calls By default the system will dial an unrestricted call and downspeed to 56kbps if necessary Example xdirectory localentry 26 restrict on LocalEntry 1 200 N...

Page 123: ...8 192 256 320 384 512 768 1152 1472 1920 2560 3072 4096 Max Auto Specifies the callrate to use when calling this entry Example xdirectory globalentry 26 callrate 1xh221 GlobalEntry 1 400 Restrict On Off Specifies wether or not to use Restrict when calling this entry A restricted call uses 56kbps channels rather than the default unrestricted 64kbps channels Some older networks primarily in the USA ...

Page 124: ... documentation php You may reset configuration settings to their default values Whether a specific configuration command will be affected by the reset command depends on two things which class es of configuration commands you want to reset and which class the specific configuration command belongs to Configuration Storage Levels ...

Page 125: ...0 30 3 OSD Mode On Off 3 PacketlossDownSpeed Mode Auto Off 1 PictureProgram 1 4 Layout Full 2Split 4Split 2 1Split 3 1Split 5 1Split 1 PictureProgram 1 4 Window 1 6 Call 1 11 1 PictureProgram 1 4 Window 1 6 Picture LocalMain LocalDuo Current Previous Duo RemoteMain RemoteDuo JPEG TandbergMonitor1 TandbergMonitor2 None NetProfile 7 Network PictureProgram 1 4 Window 1 6 Picture Tip An exhaustive desc...

Page 126: ...igital NAM None 1 Audio AutoMute On Off Unmute 1 Audio EchoControl 1 4 On Off NoiseReduction 1 Audio Feedback Mode Normal Fast 1 Audio Inputs Line 1 3 Level 1 16 1 Audio Inputs Line 1 Mode On Off Microphone 3000 MXP 1 Audio Inputs Line 2 Mode On Off Auto 3000 MXP 1 Audio Inputs Line 1 2 Mode On Off 6000 MXP 1 Audio Inputs Line 3 Mode On Off Auto 6000 MXP 1 Audio Inputs Microphone 1 3 Level 1 16 1 ...

Page 127: ... 0 21 1 AutoAnswer Delay 1 50 1 AutoAnswer Mode On Off Mute 1 AutoDisplaySnapshot On Off 1 AutoLayout Mode On Off 1 AutoPIP Mode On Off Auto 3 Bonding Timer Normal Relaxed 3 CallManager Address S 0 64 1 Camera 1 13 Backlight On Off 1 Camera 1 13 Brightness Level 0 16 1 Camera 1 13 Brightness Mode Manual Auto 1 Camera 1 13 DualVisca Off On 1 Camera 1 13 Focus Mode Manual Auto 1 Camera 1 13 Gamma Le...

Page 128: ...all On Off 1 Conference AllowIncomingTlphCall On Off 1 Conference BillingCode On Off 1 Conference DefaultCall CallRate Tlph 1xh221 2xh221 64 128 192 256 320 384 H0 512 768 1152 1472 1920 2560 3072 4096 Max Auto 1 Conference DefaultCall NetProfile 1 7 1 Conference DefaultCall Restrict On Off 2 Conference Downspeed On Off 3 Conference Encryption Mode On Off Auto 3 Conference Encryption Type Auto DES...

Page 129: ...4Split 5 1Split VS Auto 3 Conference SIP URI S 0 60 2 Conference VideoQualityCP Motion Sharpness Auto 1 Conference WebSnapshots On Off 3 CorporateDirectory Address S 0 64 3 CorporateDirectory Mode On Off 3 CorporateDirectory Path S 0 255 1 DefaultPIPPosition BottomLeft BottomRight TopLeft TopRight 1 DoNotDisturb Mode On Off 3 DualMonitor Mode On Off 1 DuoVideoSource 0 1 2 3 4 5 6 3 E1 Interface CR...

Page 130: ...0 3 G703 Interface StartChannel 1 31 3 G703 Linecoding b8zsRestrict b8zsNoRestrict 3 G703 PhysicalLayer E1 T1 3 H320 NetType BRI PRI External G703 None 3 H323 Mode On Off 3 H323CallSetup Mode Direct Gatekeeper CallManager 3 H323Gatekeeper Address S 0 64 3 H323Gatekeeper Authentication ID S 0 49 3 H323Gatekeeper Authentication Mode Auto Off 3 H323Gatekeeper Authentication Password S 0 49 3 H323Gate...

Page 131: ...er 3 IMUX Custom BW64 BW128 BW192 BW256 BW320 BW384 BW512 BW768 BW1152 BW1472 BW1920 Prefix S 0 12 3 IMUX Custom BW64 BW128 BW192 BW256 BW320 BW384 BW512 BW768 BW1152 BW1472 BW1920 Suffix S 0 12 3 IMUX Custom BW64R BW128R BW192R BW256R BW320R BW384R BW512R BW768R BW1152R BW1472R BW1920R Prefix S 0 12 3 IMUX Custom BW64R BW128R BW192R BW256R BW320R BW384R BW512R BW768R BW1152R BW1472R BW1920R Suffi...

Page 132: ...0 20 1 ISDN BRI InterfaceSearch High Low 3 ISDN BRI MaxDeactiveTime 1 60 3 ISDN BRI SwitchType NI ATT Euro 1TR6 Japan Australia FETEX 1 ISDN CliNumbPlan 0 14 1 ISDN CliNumbSpec On Off 1 ISDN CliNumbType 0 6 3 ISDN HLC On Off 3 ISDN MSN On Off 3 ISDN ParallelDial On Off 3 ISDN PRI Alert On Off 3 ISDN PRI ChanId On Off 3 ISDN PRI InitialRestart On Off 3 ISDN PRI Interface HighChannel 1 31 3 ISDN PRI...

Page 133: ...ers On Off 3 ISDN SubAddress S 0 20 1 Keyboard Layout English US Norwegian Swedish German French User 1 Kiosk AllowIRControl On Off 1 Kiosk AutoDial On Off 1 Kiosk LanguageMenu English On Off 1 Kiosk LanguageMenu French On Off 1 Kiosk LanguageMenu German On Off 1 Kiosk LanguageMenu Italian On Off 1 Kiosk LanguageMenu Mode On Off 1 Kiosk LanguageMenu Norwegian On Off 1 Kiosk LanguageMenu Spanish On...

Page 134: ...3 MCU MultiSite On Off 3 MCU MultiWay On Off 3 NAT Address IPAddr 3 NAT Mode On Off Auto 3 NetProfile 1 7 CallPrefix S 0 9 3 NetProfile 1 7 CallSuffix S 0 30 3 NetProfile 1 7 Name S 0 8 3 NetProfile 1 Network Auto 3 NetProfile 2 Network H320 3 NetProfile 3 Network H323 3 NetProfile 4 Network H320 H323 SIP Auto 3 NetProfile 5 Network H320 H323 SIP Auto 3 NetProfile 6 Network H320 H323 SIP Auto 3 Ne...

Page 135: ...talian Portuguese Japanese Chinese TraditionalChinese Russian Spanish Korean Finnish Thai Arabic 3 OSD Menu Mode On Off 3 OSD Menu Password S 0 5 3 OSD Menu WelcomeMenu On Off 2 OSD Menu WelcomeText S 0 30 3 OSD Mode On Off 1 OSD Offset Mode On Off 3 PacketlossDownSpeed Mode Auto Off 1 PictureProgram 1 4 Layout Full 2Split 4Split 2 1Split 3 1Split 5 1Split 1 PictureProgram 1 4 Window 1 6 Call 1 11...

Page 136: ... QoS Diffserv VideoTelephony Audio 0 63 3 QoS Diffserv VideoTelephony Data 0 63 3 QoS Diffserv VideoTelephony Signalling 0 63 3 QoS Diffserv VideoTelephony Video 0 63 3 QoS Mode Precedence Diffserv Off 3 QoS Precedence Telephony Audio 0 1 2 3 4 5 6 7 Auto Off 3 QoS Precedence Telephony Signalling 0 1 2 3 4 5 6 7 Auto Off 3 QoS Precedence VideoTelephony Audio 0 1 2 3 4 5 6 7 Auto Off 3 QoS Preceden...

Page 137: ...ty None Odd Even 3 SerialPort 1 2 StopBits 1 2 3 SerialPort 1 Mode Control Transparent 3 SerialPort 2 Mode VISCA Auto 3 SIP Authentication Password S 0 60 3 SIP Authentication UserName S 0 80 3 SIP Mode On Off 3 SIP Server Address S 0 255 3 SIP Server Discovery Manual Auto 3 SIP Server Type Auto Nortel Microsoft Cisco Alcatel Experimental 3 SIP TLS Verify On Off 3 SIP Transport Default Auto TCP UD...

Page 138: ...Quality Motion Sharpness 3 Streaming Source Local Remote Auto 3 Streaming VideoRate 16 32 64 128 192 256 320 1 StrictPassword On Off 3 SystemUnit DisplayName S 0 50 3 SystemUnit InternationalName S 0 49 3 SystemUnit Name S 0 49 3 SystemUnit Password S 0 16 3 T1 Interface CableLength Range1 Range2 Range3 Range4 Range5 1 Telnet Mode On Off 1 TelnetChallenge Mode On Off 1 TelnetChallenge Port 23 57 1...

Page 139: ... Video Outputs DVI 1 2 OSD On Off 1 Video Outputs DVI 1 2 VirtualMonitor 1 4 1 Video Outputs DVIResolution 1 2 Auto SVGA XGA 3 Video Outputs FormatPCWideScreen Normal Wide 3 Video Outputs Letterbox On Off 1 Video Outputs TestPattern 0 10 1 Video Outputs TV 1 2 Mode On Off 1 Video Outputs TV 1 2 OSD On Off 1 Video Outputs TV 1 2 VirtualMonitor 1 4 3 Video Outputs ScreenFormatPC 4 3 16 9 3 Video Out...

Page 140: ...u check out the TANDBERG web site regularly for updated versions of this manual http www tandberg com support documentation php This part of the manual describes the Command Information available Command Information Tables ...

Page 141: ...ter software upgrade all configurations will be restored By setting ParameterRestore to Off the system configurations prior to software upgrade will be lost None As above xcommand boot parameterrestore on r Result status OK r end OK CallAccept Command used to answer an incoming call if autoanswer is disabled None None As above xcommand callaccept r Result status OK r end OK CallMute Command used to ...

Page 142: ...annel with a specific test signal sine white noise or pink noise When the command is issued the system will send out the specified test signal to the specified output channel Type r None Sine White Pink The test signal Level 60 0 Level in dB The level is dependent on the output level settings on the system When the output levels are set to default level settings 0 dB will correspond to 1 Vrms If n...

Page 143: ...swer an incoming call if autoanswer is disabled None None As above xcommand callaccept r Result status OK r end OK CallMute Command used to mute incoming audio from a specific call in a Multi Site conference Call r 1 11 Reference to the call to be muted or unmuted Mode r On Off Denotes whether the call is to be muted or unmuted None As above xcommand callmute call 2 mode on r Result status OK r en...

Page 144: ...o change focus of a spe cific camera Camera r 1 13 Addresses which camera to have its focus changed Value r Auto Manual Specifies the wanted operation None As above xcommand camerafocus camera 1 value r Result status OK r end OK CameraForceUpgrade Command used to initiate software upgarde of the TANDBERG Precision HD Camera Should only be used after downgrade of the TANDBERG MXP Codec software or ...

Page 145: ...t Specifies the direction to move None As above xcommand cameramove camera 1 direction right r Result status OK r end OK CameraPosition Command used to instruct the camera to move to a specific position Camera r 1 13 Addresses the camera to position Pan 32768 32767 Pan value Tilt 32768 32767 Tilt value Zoom 0 65534 Zoom value Focus 0 65534 Focus value Note The supported values for pan tilt zoom fo...

Page 146: ...re The software must be put on a folder named either tmp or user Currently only upgrading of the first camera or video switch is supported r 1 13 filename Addresses the specific camera or TANDBERG Video Switch Camera software files are named s01692 pkg Video Switch software files are named s51200 pkg None As above xcommand cameraupgrade 1 s01692 pkg r Result status OK r end OK CameraWhiteBalance C...

Page 147: ...t parameters when OK Result parameters when error Example ConferenceDisconnect Command used to disconnect all calls connected to the system None None As above xcommand ConferenceDisconnect r Result status OK r end OK ConferenceTerminate ConferenceTerminate is only valid if the system is participant in a MultiSite conference supporting Chair Control and for the system granted chair The command will...

Page 148: ...he query to search for StartsWith S 0 81 The search string should start with Hits 1 40 Specify the number of hits to show SubFolders On Off Define if the search should also include subfolders IsFirst True False True indicates that this is the first hit matching the search criteria False indicates that this is not the first hit matching the search criteria CorpDirGetPrevious can be used to search f...

Page 149: ... 0 256 Enter the path which is the ID of the folder or subfolder to search in The result will show the first 40 entries in the given catalog If no catalog specified by Path then the root catalog is used Query S 0 81 Enter the query to search for StartsWith S 0 81 The search string should start with Hits 1 40 Specify the number of hits to show ID S 0 21 Define the ID of an entity The ID is relative...

Page 150: ...nter the path which is the ID of the folder or subfolder to search in The result will show the first 40 entries in the given catalog If no catalog specified by Path then the root catalog is used Query S 0 81 Enter the query to search for StartsWith S 0 81 The search string should start with Hits 1 40 Specify the number of hits to show ID S 0 21 Define the ID of an entity The ID is relative to a sp...

Page 151: ...dtosavespaceinthetables Command Description Parameters Result parameters when OK Result parameters when error Example DefaultValuesSet Command used to reset configurations to factory default values Level 1 3 Configurations are divided into three different storage levels The level parameter denotes that configurations on this level and all levels below lower value are to be reset The complete list ...

Page 152: ...e The CallRates supported for a system will depend on model and software options Restrict On Off A restricted call uses 56kbps channels rather than the default unrestricted 64kbps channels Some older networks primarily in the USA do not support 64kbps channels and require the use of restricted 56kbps calls By default the system will dial an unrestricted call and downspeed to 56kbps if necessary Ne...

Page 153: ...alentry id 19 r Result status OK CallRef 1 LogTag 312 r end OK DialGroupEntry Command used to dial an entry from the Group Directory Dialling from the Group Directory makes it possible to set up a MultiSite conference in one operation GroupEntryId r 1 50 Reference to the directory entry to be dialed The system will return the following elements for each call initiated CallRef 1 11 Reference to the...

Page 154: ... H 239 from the system VideoSource 1 6 Specifies which video source to be used for the additional video stream If this parameter is omitted the system will use the default DuoVideo source configured for the system ref configuration DuoVideoSource None As above xcommand duovideostart videosource 5 r Result status OK r end OK DuoVideoStop Command used to stop DuoVideo H 239 None None As above xcomma...

Page 155: ...o activate a far end preset Number r 0 15 The preset number to activate None As above xcommand feccpresetactivate number 4 r Result status OK r end OK FECCPresetStore Command used to store a far end preset Number r 0 15 The preset number to store None As above xcommand feccpresetstore number 4 r Result status OK r end OK FECCRequestStill Command used to request a still image from a specific source...

Page 156: ... to be registered with a maximum of 15 for a single URL ID 1 3 ID for the registration If this parameter is omitted the system uses the first vacant ID URL r S 0 256 The URL to post feedback to Expression 1 15 S 0 256 XPath expression ID 1 3 As above xcommand feedbackregister url http 10 47 14 185 8000 expression 1 status call expression 2 status conference r Result status OK ID 2 r end OK FIPSMod...

Page 157: ...teend r Result status OK r end OK GroupEntryAdd Command used to add a new Group entry to the locally stored Group Directory or MultiSite Directory The entry is stored in the first vacant position in the Group Directory Name S 0 48 The entry s name LocalEntryId 1 10 1 200 References to local entry ids to be included in this Group entry GroupEntryId 1 50 Reference to the Group Directory position the...

Page 158: ...ase key phonebook r Result status OK r end OK KeyPress Command used to emulate pressing a key on the TANDBERG MXP remote control for a short while This command needs no release command Key r 0 1 2 3 4 5 6 7 8 9 Connect Disconnect Up Down Right Left Selfview Layout Phonebook Cancel MicOff Presentation VolumeUp VolumeDown OK ZoomIn ZoomOut Grab None As above xcommand keypress key phonebook r Result ...

Page 159: ...ond number 2XH221 number SubAddress S 0 10 The entry s sub address CallRate Tlph 1xh221 2xh221 64 128 192 256 320 384 512 768 115 2 1472 1920 2560 3072 4096 H0 Max Auto The callrate to use when calling this entry Restrict On Off Whether to use restrict or not when calling this entry NetProfile 1 7 The Net Profile to use when calling this entry LocalEntryId 1 200 Reference to the Directory position...

Page 160: ...P on a specific VirtualMonitor VirtualMonitor r 1 4 Addresses which VirtualMonitor to apply the command None As above xcommand piphide virtualmonitor 1 r Result status OK r end OK PIPShow Command used to display a specific picture in a PIP on a selected VirtualMonitor VirtualMonitor r 1 4 Addresses which VirtualMonitor to apply the command Picture r LocalMain LocalDuo RemoteMain RemoteDuo JPEG Tan...

Page 161: ...d presetstore number 4 r Result status OK r end OK ProfileActivate Command to activate an existing user profile Name r S 0 16 The name of the user profile to activate None As above xcommand profileactivate profilename r Result status OK r end OK ProfileCreate Configure the video system and use this command to create a new user profile Name r S 0 16 The name of the user profile to create None As ab...

Page 162: ...one As above xcommand screensaverreset delay 90 r Result status OK r end OK SiteDisconnect Command used to disconnect a specific site from a MultiSite conference supporting H 243 MCUID r 1 191 MCUID to the MultiSite the site is connected to TerminalID r 1 191 The site s terimnal id referenced to the MultiSite it is connected to None As above xcommand sitedisconnect mcuid 85 termi nalid 2 r Result ...

Page 163: ...age If this parameter is omitted the system will use the default still image source configured for the system None As above xcommand stillimagesend videosource 5 r Result status OK r end OK StreamingStart Command used to start streaming from the system None None As above xcommand streamingstart r Result status OK r end OK StreamingStop Command used to stop streaming from the system None None As ab...

Page 164: ...sult status OK r end OK VirtualMonitorSet Command used to instruct the system to display a specific picture on a specific VirtualMonitor A VirtualMonitor can be displayed on one or more of the local video outputs which VirtualMonitor a specific video output is to display is configurable When this command is issued for a specific VirtualMonitor the picture displayed on this monitor will not change ...

Page 165: ... versions of this manual http www tandberg com support documentation php This part of the manual describes the Status information available There are three types of status information available xstatus status xml xhistory history xml xevent event xml Status Information Tables ...

Page 166: ...allRef 1 s end If type PointToMultiSite the following will be included Calls CallRef 1 11 1 11 DuoVideo status None Ready On If status None Ready the following will be included Nothing Conference Status Information The status element listed on this page Indenting is used to keep track of the levels In the tables one light grey square is used per level This condition causes this to appear The means...

Page 167: ... XACLI Special commands xpreferences Audio AudioModule None NAMI NAMII Digital NAM mDNAM Inputs Microphone 1 3 Active True False Line 1 3 Active True False Example s Audio AudioModule None Inputs Microphone 1 Active True Microphone 2 Active False Microphone 3 Active False Line 1 Active False Line 2 Active False Line 3 Active False s end Audio Status Information xstatus xstatus xml ...

Page 168: ...d Channel 1 2 type BChannel status Idle Calling Answering Proceeding Connect Disconnecting Disconnected If type Bchannel and status Idle the following will be included Nothing If type Bchannel and status Calling Answering Proceeding Connect the following will be included CallingNumber ConnectionTime If type Bchannel and status Disconnecting Disconnected the following will be included CallingNumber...

Page 169: ...annel status Idle Channel 2 type BChannel status Disconnected CallingNumber 8770 CauseLocation 0 ChannelCause 41 ConnectionTime 258 s end s BRI 2 ready True Channel 1 type BChannel status Connect CallingNumber 8770 ConnectionTime 346 Channel 2 type BChannel status Connect CallingNumber 8770 ConnectionTime 346 s end s BRI 3 ready True Channel 1 type BChannel status Connect CallingNumber 8770 Connec...

Page 170: ...ing logTag 1 x If status Disconnected and type NA and protocol NA and direction NA and logtag x the following will be included Cause If status Dialing Alerting Proceeding EstablOut EstablIn AwaitInCnf Connected Disconnecting Await2ndnr ClearOut ClearIn Syncing Capex Synced Unframed and type Tlph and protocol ISDN and direction Incoming Outgoing and logTag x the following will be included CallRate ...

Page 171: ...atus Active the following will be included Protocol G711 G722 G722 1 G728 AAC LD Rate 16 Example s Call 1 status Synced type Tlph protocol ISDN direction Incoming logTag 5944 CallRate 64 RemoteNumber 1 8733 RemoteNumber 2 RemoteSubAddress IncomingNumber 8770 IncomingSubAddress Mute Off Microphone On Duration 127 MuteOutgoing Off Channels 1 type Incoming Rate 64 Restrict Off Audio status Active Pro...

Page 172: ...going and logTag x the following will be included CallRate 64 128 4096 RemoteNumber 1 2 RemoteSubAddress IncomingNumber Appears for incoming calls only IncomingSubAddress Mute On Off Microphone On Off Duration 0 MuteOutgoing On Off Channels 1 2 type Incoming Outgoing If type Incoming Outgoing the following will be included Rate 64 4096 Restrict On Off Encryption status Off Negotiate On If status O...

Page 173: ...722 1 G728 AAC LD Rate Video 1 2 status Active Inactive If status Inactive the following will be included Nothing If status Active the following will be included Protocol H261 H263 H263 H264 Resolution QCIF SQCIF CIF 2CIF 4CIF ICIF SIF 4SIF ISIF VGA SVGA XGA QVGA 448p 400p w288p w448p w576p w720p Rate Data status Active Inactive If status Inactive the following will be included Nothing If status A...

Page 174: ...umber 1 8776 RemoteNumber 2 RemoteSubAddress Mute Off Microphone On Duration 32 MuteOutgoing Off Channels 1 type Incoming Rate 384 Restrict Off Encryption status On Type AES 128 CheckCode BA8C78DAD933C3DD Audio status Active Protocol AAC LD Rate 64 Video 1 status Active Protocol H264 Resolution 2 5SIF Rate 317 Video 2 status Inactive Data status Inactive Channels 2 type Outgoing Rate 384 Restrict ...

Page 175: ... and protocol H323 SIP and direction Incoming Outgoing and logTag x the following will be included CallRate 64 RemoteNumber RemoteSubAddress IncomingNumber Appears for incoming calls only IncomingSubAddress Mute On Off Microphone On Off Duration 0 MuteOutgoing On Off Channels 1 2 type Incoming Outgoing If type Incoming Outgoing the following will be included Rate 64 4096 Restrict On Off Encryption...

Page 176: ...ing Off Channels 1 type Incoming Rate 64 Restrict Off Encryption status On Type AES 128 CheckCode E2957C90C5DF0649 Audio status Active Protocol G711 Rate 64 RemoteIPAddress LocalIPAddress 10 47 20 59 2334 Encryption status On Type AES 128 RSVP Off RSVPRate 0 DynamicRate 64 TotalPackets 725 PacketLoss 0 Jitter 0 PacketsDropped 0 Data status Inactive Channels 2 type Outgoing Rate 64 Restrict Off Enc...

Page 177: ...P and direction Incoming Outgoing and logTag x the following will be included CallRate 64 128 4096 RemoteNumber RemoteSubAddress IncomingNumber Appears for incoming calls only IncomingSubAddress Mute On Off Microphone On Off Duration 0 MuteOutgoing On Off Channels 1 2 type Incoming Outgoing If type Incoming Outgoing the following will be included Rate 64 4096 Restrict On Off Encryption status Off ...

Page 178: ...tatus Off the following will be included Nothing If status On the following will be included Type DES AES 128 RSVP On Off DynamicRate TotalPackets PacketLoss Jitter PacketsDropped Appears for incoming calls only Video 1 2 status Active Inactive If status Inactive the following will be included Nothing If status Active the following will be included Protocol H261 H263 H263 H264 Resolution QCIF SQCI...

Page 179: ...amicRate TotalPackets PacketLoss Jitter PacketsDropped Appears for incoming calls only Data status Active Inactive If status Inactive the following will be included Nothing If status Active the following will be included Type LSD MLP Protocol FECC Rate RemoteIPAddress LocalIPAddress Encryption status On Off If status Off the following will be included Nothing If status On the following will be inc...

Page 180: ...5020059 IncomingSubAddress Mute Off Microphone On Duration 10 MuteOutgoing Off Channels 1 type Incoming Rate 768 Restrict Off Encryption status On Type AES 128 CheckCode C442803A9A470B7F Audio status Active Protocol AAC LD Rate 64 RemoteIPAddress LocalIPAddress 10 47 20 59 2334 Encryption status On Type AES 128 RSVP Off RSVPRate 0 DynamicRate 64 TotalPackets 474 PacketLoss 0 Jitter 1 PacketsDroppe...

Page 181: ...68 Restrict Off Encryption status On Type AES 128 CheckCode C442803A9A470B7F Audio status Active Protocol AAC LD Rate 64 RemoteIPAddress 10 47 20 19 2334 LocalIPAddress 10 47 20 59 2334 Encryption status On Type AES 128 RSVP Off RSVPRate 0 DynamicRate 63 TotalPackets 475 PacketLoss 0 Jitter 2 Video 1 status Active Protocol H264 Resolution 2 5SIF Rate 704 RemoteIPAddress 10 47 20 19 2336 LocalIPAdd...

Page 182: ...MAY 2008 Status information followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences Camera 1 13 connected True False Type ID Pan Tilt Zoom Focus Example s Camera 1 connected True Type WaveII ID 0c0e0006 SoftwareID Pan 647 Tilt 172 Zoom 0 Focus 27501 s end Camera ...

Page 183: ...atus Information xstatus xstatus xml D13887 08 MAY 2008 Status information followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences CameraSWUpgrade status N A Example s CameraSwUpgrade status NA s end CameraSWUpgrade ...

Page 184: ...8 MAY 2008 Status information followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences CameraTracking status On Off If status On Off the following will be included Nothing Example s CameraTracking status Off s end s CameraTracking status On s end CameraTracking ...

Page 185: ...Conference type Idle s end If type PointToPoint the following will be included Calls CallRef 1 11 1 11 DuoVideo status None Ready On If status None Ready the following will be included Nothing If status On the following will be included CallRef 1 11 0 11 LoudestParticipant CallRef 0 11 Example s Conference type PointToPoint Calls CallRef 1 1 DuoVideo status Ready LoudestParticipant CallRef 1 s end...

Page 186: ...be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences If status On the following will be included CallRef 1 11 0 11 LoudestParticipant CallRef 0 11 NumberOfSites 1 191 MCUSiteList Site 1 191 MCUID TerminalID Name CallRef LocalSite Self MCUID TerminalID OnAir On Off Floor On Off Chair UnSupported View MCUID TerminalID Conference cont ...

Page 187: ... 1 NumberOfSites 3 MCUSiteList Site 1 MCUID 85 TerminalID 3 Name Boardroom1 CallRef 1 Site 2 MCUID 85 TerminalID 1 Name Boardroom2 CallRef None Site 3 MCUID 85 TerminalID 2 Name Boardroom3 CallRef None LocalSite Self MCUID 85 TerminalID 3 OnAir On Floor Off Chair UnSupported View MCUID 0 TerminalID 0 s end If type MultiSite the following will be included Calls CallRef 1 11 1 11 DuoVideo status Non...

Page 188: ... None FloorRequest FloorAssign Current CallRef 0 11 Previous CallRef 0 11 OutgoingPicture 1 3 name Current Previous Duo If name Current Previous Duo the following will be included Layout type Full 4Split 5 1Split Window 1 6 Picture LocalMain RemoteMain CallRef 0 11 MCUID 1 CascadingMode StandAlone Master Slave NumberOfSites 1 191 MCUSiteList Site 1 191 MCUID TerminalID Name CallRef LocalSite Self ...

Page 189: ... Calls CallRef 1 1 CallRef 2 2 DuoVideo status Ready LoudestParticipant CallRef 2 Floor None Current CallRef 2 Previous CallRef 1 OutgoingPicture 1 name Current Layout type Full Window 1 Picture RemoteMain CallRef 2 OutgoingPicture 2 name Previous Layout type Full Window 1 Picture RemoteMain CallRef 1 OutgoingPicture 3 name Duo Layout type NA MCUID 1 CascadingMode StandAlone NumberOfSites 3 MCUSit...

Page 190: ...llowed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences Continued from the previous page Name john doe 150 CallRef 2 Site 3 MCUID 1 TerminalID 4 Name john doe mxp CallRef 0 LocalSite Self MCUID 1 TerminalID 4 OnAir Off Floor Off Chair UnSupported View MCUID 1 TerminalID 3 s end Conference cont ...

Page 191: ... xstatus xml D13887 08 MAY 2008 Status information followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences Ethernet MacAddress Speed 10half 10full 100half 100full Example s Ethernet MacAddress 00 50 60 01 85 F1 Speed 100full s end Ethernet ...

Page 192: ...8 Status information followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences ExternalManager Address Protocol HTTP HTTPS URL Example s ExternalManager Address 10 47 6 75 Protocol HTTP URL tms public external management SystemManagementService asmx s end ExternalManager ...

Page 193: ...ady False the following will be included Nothing If ready True the following will be included ExternalClockRate Channel status Idle Calling Answering Proceeding Connect Disconnecting Disconnected If status Idle the following will be included Nothing If status Calling Answering Proceeding Connect the following will be included CallingNumber ConnectionTime If status Disconnecting Disconnected the fo...

Page 194: ...see XACLI Special commands xpreferences FarEndInformation FECC status On Off If status Off the following will be included Nothing T140 Off SString Off Example s FarEndInformation FECC status Off T140 Off SString Off s end If status On the following will be included NumberOfPresets x NumberOfSources x Source 1 x Name Capabilities ptzfms CurrentSource BroadcastSwitch On Off T140 On Off Sstring On Of...

Page 195: ...as been set to 2 see XACLI Special commands xpreferences Example s FarEndInformation FECC status On NumberOfPresets 15 NumberOfSources 5 Source 1 Name main cam Capabilities ptzfms Source 2 Name aux Capabilities ms Source 3 Name doc cam Capabilities ms Source 4 Name vcr Capabilities ms Source 5 Name pc Capabilities ms CurrentSource 1 BroadcastSwitch On T140 On SString On s end FarEndInformation con...

Page 196: ...es Feedback 1 3 status On Off If status Off the following will be included Nothing Example s Feedback 1 status Off s end If status On the following will be included URL Expression 1 15 Example s Feedback 2 status On URL http 10 47 6 75 tms public feedback code aspx Expression 1 History Call Expression 2 Status Call status Synced Expression 3 Status SoftwareUpgrade Expression 4 Status BRI Expressio...

Page 197: ...wing will be included Layer1Alarm RedAlarm YellowAlarm BlueAlarm If ready True the following will be included Channel 1 24 31 status NA Idle Calling Answering Proceeding Connect Disconnecting Disconnected If status NA Idle the following will be included Nothing If status Calling Answering Proceeding Connect the following will be included CallingNumber ConnectionTime If status Disconnecting Disconn...

Page 198: ...ing Registered Rejected Inactive If status Inactive the following will be included Nothing Example s H323Gatekeeper status Inactive s end If status Required Discovering Discovered Authenticating Authenticated Registering Registered the following will be included Alias Address Port Example s H323Gatekeeper status Registered Alias 5584582 Address 10 47 9 1 Port 1719 s end If status Rejected the foll...

Page 199: ...n set to 2 see XACLI Special commands xpreferences IP Address SubnetMask Gateway V6 Adress 1 2 type NA IPv4 IPv6 DNS Server 1 5 Address Domain Name Example s IP Address 10 47 11 179 SubnetMask 255 255 248 0 Gateway 10 47 8 1 V6 Address 1 type NA Address 2 type NA DNS Server 1 Address 10 0 0 10 Server 2 Address 10 0 0 2 Server 3 Address Server 4 Address Server 5 Address Domain Name eu tandberg int ...

Page 200: ...M INTEGRATORS Status Information xstatus xstatus xml D13887 08 MAY 2008 Status information followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences NTP Address Example s NTP Address 10 0 0 2 s end NTP ...

Page 201: ...arm RedAlarm s end If ready True the following will be included Channel 1 24 31 type BChannel DChannel status NA Idle Calling Answering Proceeding Connect Disconnecting Disconnected If type DChannel and status NA the following will be included Nothing If type BChannel DChannel and status Idle the following will be included Nothing If type BChannel and status Calling Answering Proceeding Connect th...

Page 202: ... 1 ConnectionTime 0 Channel 4 type BChannel status Disconnected CallingNumber 08733 CauseLocation 0 ChannelCause 16 ConnectionTime 120 Channel 5 type BChannel status Disconnected CallingNumber 08733 CauseLocation 0 ChannelCause 16 ConnectionTime 120 Channel 6 type BChannel status Disconnected CallingNumber 08733 CauseLocation 0 ChannelCause 16 ConnectionTime 120 Channel 7 type BChannel status Disc...

Page 203: ...d CallingNumber 08733 CauseLocation 0 ChannelCause 16 ConnectionTime 56 Channel 14 type BChannel status Disconnected CallingNumber 08733 CauseLocation 0 ChannelCause 16 ConnectionTime 56 Channel 15 type BChannel status Disconnected CallingNumber 08733 CauseLocation 0 ChannelCause 16 ConnectionTime 113 Channel 16 type BChannel status Idle Channel 17 type BChannel status Idle Channel 18 type BChanne...

Page 204: ...estoringSettings Failed WrongPassword Granted NoDataLink WrongFormat ErrorWrite WrongReleaseKey Incompatible FileToo Large Requesting If status Started the following will be included Progress Example s RemoteSwUpgrade status Started Progress 12 s end If status NA Checking Completed Aborted NotValid RestoringSettings Failed WrongPassword Granted NoDataLink WrongFormat ErrorWrite WrongReleaseKey Inc...

Page 205: ...ion followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences Screensaver status On Off If status On the following will be included Nothing Example s Screensaver status On s end If status Off the following will be included Timer Example s Screensaver status Off Timer 37 s end Screensaver ...

Page 206: ...nknown If status Inactive the following will be included Nothing If status DNSFailed Timeout NoConnectionTCP NoConnectionTLS Active Unknown the following will be included Address Authentication On Off Registration status Inactive Registering Registered Deregister Failed If status Inactive Registering Registered Deregister the following will be included URI If status Failed the following will be in...

Page 207: ...e XACLI Special commands xpreferences SoftwareUpgrade status NA Started Checking Completed Aborted NotValid RestoringSettings Failed If status Started the following will be included Progress Example s SoftwareUpgrade status Started Progress 12 s end If status NA Checking Completed Aborted NotValid RestoringSettings Failed the following will be included Nothing Example s SoftwareUpgrade status NA s...

Page 208: ...ync 2 Sync 3 Sync 4 Example s Switch connected True Input 1 Format 1280X720p60 Sync True Sync 1 True Sync 2 True Sync 3 False Sync 4 False s end Info xstatus switch will give information about sync status for the active input the format and sync status for all DVI D inputs Active input may differ from what is given in the xconfiguration Switch Source setting This is because an external control sys...

Page 209: ... see XACLI Special commands xpreferences SystemUnit ProductType ProductId Uptime Software Version Name ReleaseDate Configuration Telephony VideoTelephony TotalBandwidth ISDNBandwidth LANBandwidth PresenterOption True False MultisiteOption True False StreamingSupport True False Encryption True False Hardware SerialNumber MainBoard AdditionalBoard BootSoftware Configuration PRI BRI ExternalNetwork V...

Page 210: ...e TANDBERG Codec ProductId TANDBERG 6000MXP PORTABLE Uptime 10136 Software Version F4 0Beta2 NTSC Name s50000 ReleaseDate 2005 11 17 Configuration Telephony 5 VideoTelephony 5 TotalBandwidth 6144 ISDNBandwidth 1920 LANBandwidth 4096 PresenterOption True MultisiteOption True StreamingSupport True Encryption True Hardware SerialNumber 25A00309 MainBoard 100670 rev 05 AdditionalBoard BootSoftware Rev...

Page 211: ...e Full 2Split 2 1Split 3 1Split 4Split 5 1Split persistent On Off Window 1 6 Picture LocalMain LocalDuo Current Previous Duo RemoteMain RemoteDuo JPEG Still None CallRef 1 11 Example s VirtualMonitor 1 Layout type 3 1Split persistent Off Window 1 Picture RemoteMain CallRef 1 Window 2 Picture Local Main CallRef 0 Window 3 Picture NA CallRef 0 Window 4 Picture NA CallRef 0 PIP status Off s end s Vir...

Page 212: ...s detected you will not be able to place calls 191 Warning G 703 Layer 1 Red Alarm Red alarm or Loss of signal LOS means that there is no signal and thus no framing information received this has the same effect as pulling out the PRI cable 192 Warning G 703 Layer 1 Blue Alarm Blue alarm indicates that the network on the far side of the CSU is unavailable 193 Warning G 703 Layer 1 Yellow Alarm Yell...

Page 213: ...Duration UptimeAtEndOfCall BillingCode Audio PacketsReceived PacketsLost PacketsDropped DurationLossLevel1 DurationJitterLevel1 NumberOfLevel1Bursts DurationLossLevel2 DurationJitterLevel2 NumberOfLevel2Bursts Video PacketsReceived PacketsLost PacketsDropped DurationLossLevel1 DurationJitterLevel1 NumberOfLevel1Bursts DurationLossLevel2 DurationJitterLevel2 NumberOfLevel2Bursts Disconnect Cause Ov...

Page 214: ...FullRegistrtionRequired GatekeeperResources GatewayResources GenericDataReason IncompleteAddress InConf InsufficientResources InvalidAlias InvalidCallSignalAdr InvalidConferenceID InvalidDestinationURL InvalidEndpointID InvalidPermission InvalidRASAdr InvalidRevision InvalidSDP InvalidTerminalAlias InvalidTerminalName MasterSlaveFailed NeededFeatureNotSupported NewConnectionNeeded NoBandwidth NonS...

Page 215: ...d for reuse by the preempting exchange Cause No 16 Normal Call Clearing This cause indicates that the call is being cleared because one of the users involved in the call has requested that the call be cleared Cause No 16 4 or 17 User Busy This cause is used when the called user has indicated the inability to accept another call This cause code may be generated by the called user or by the network ...

Page 216: ... Of Service Not Available This cause is used to report that the requested Quality of Service can not be provided delay canít be supported Cause No 50 Requested facility not subscribed This cause indicates that the requested supplementary service could not be provided due to user oversight This cause code is often caused by the CPE being configured for the wrong switch type Cause No 52 Outgoing cal...

Page 217: ...t Is Missing This cause indicates that the equipment sending this cause has re ceived a message which is missing an information element which must be present in the message before that message can be processed Cause No 97 Message Type Non Existent Or Not Implemented This cause indicates that the equipment sending this cause has received a message with a message type it does not recognize either be...

Page 218: ...ed Level has been set to 2 see XACLI Special commands xpreferences AuthenticationFailure Service RemoteIPAddress Uptime Example Polling e AuthenticationFailure Service RemoteIPAddress Uptime e end Feedback e AuthenticationFailure Service FTP RemoteIPAddress 10 47 11 82 1459 Uptime 417490 e end AuthenticationFailure Status Information xevent xevent xml ...

Page 219: ...followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences CallDisconnected CallRef LogTag Example Polling e CallDisconnected CallRef LogTag e end Feedback e CallDisconnected CallRef 2 LogTag 11 e end CallDisconnected Status Information xevent xevent xml ...

Page 220: ...uccessful CallRef LogTag Protocol Direction CallRate RemoteNumber Encryption Incoming Outgoing Example Polling e CallSuccessful CallRef LogTag Protocol Direction CallRate RemoteNumber Encryption Incoming Outgoing e end Feedback e CallSuccessful CallRef 1 LogTag 12 Protocol H323 Direction Outgoing CallRate 768 RemoteNumber 558458 Encryption Incoming Off Outgoing Off e end CallSuccessful Status Info...

Page 221: ...l not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences DownspeedingFinished CallRef LogTag Rate Example Polling e DownspeedingFinished CallRef LogTag Rate e end Feedback e DownspeedingFinished CallRef 3 LogTag 7 Rate 384 e end DownspeedingFinished Status Information xevent xevent xml ...

Page 222: ...s information followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences MessageBoxResult Button Example Polling e MessageBoxResult Button e end Feedback e MessageBoxResult Button 1 e end MessageBoxResult Status Information xevent xevent xml ...

Page 223: ...008 Status information followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences PacketlossDownSpeed CallRef LogTag Example Polling e PacketlossDownSpeed CallRef LogTag e end PacketlossDownSpeed Status Information xevent xevent xml ...

Page 224: ...887 08 MAY 2008 Status information followed by a will not be shown unless Detailed Level has been set to 2 see XACLI Special commands xpreferences SString Example Polling e SString e end Feedback e SString Testing SString e end SString Status Information xevent xevent xml ...

Page 225: ...el has been set to 2 see XACLI Special commands xpreferences SystemActivity Service RemoteIPAddress Uptime Description Example Polling e SystemActivity Service RemoteIPAddress Uptime Description e end Feedback e SystemActivity Service FTP RemoteIPAddress Unknown Uptime 417995 Description get all prm e end SystemActivity Status Information xevent xevent xml ...

Page 226: ... connected to an external control system and that you want to be able to control these cameras using the TANDBERG remote or from the remote site using FECC Far End Camera Control To do this you will need to make use of the Extcam Protocol This section of the Reference User Guide explains Extcam Protocol Basics as well as how to interface to the TANDBERG WAVE II camera and the TANDBERG Precision HD...

Page 227: ...ll the codec will send out a camera video source capset consisting of video source names as specified by the vid name command and capabilities as detected by the internal camera driver If you have start ed extcam with the source n option these capabilities and names will probably not match with what you have in your control system So when you use the source n option the names and capabilities spec...

Page 228: ... single camera the address is 1 Hence address bytes in mes sages from the host are 0x81 and messages from the camera to the host are 0x90 the protocol allows for up to 7 cameras 2 Message bytes Any number of bytes containing the actual mes sage information Bytes may have any value in the range 0 254 The value 255 i e hexadecimal FF is reserved for the terminating byte 3 Terminating byte All messag...

Page 229: ...nquiry 81 09 04 47 FF Response 90 50 00 0q 0r 0s FF qrs zoom posistion Tilt up start 81 01 06 01 0p 0t 03 01 FF p pan speed t tilt speed low 0 high 7 Tilt down start 81 01 06 01 0p 0t 03 02 FF Pan left start 81 01 06 01 0p 0t 01 03 FF Pan right start 81 01 06 01 0p 0t 02 03 FF Pan tilt stop 81 01 06 01 03 03 03 03 FF Pan tilt direct 81 01 06 02 0p 0t 00 0x 0y 0z 00 00 0u 0v FF p pan speed t tilt s...

Page 230: ...4 0A 00 FF Shutter Up 81 01 04 0A 02 FF Shutter Down 81 01 04 0A 03 FF Gain Reset 81 01 04 0B 00 FF Gain Up 81 01 04 0B 02 FF Gain Down 81 01 04 0B 03 FF Bright Reset 81 01 04 0D 00 FF Bright Up 81 01 04 0D 02 FF Bright Down 81 01 04 0D 03 FF IR on 81 01 06 08 02 FF IR off 81 01 06 08 03 FF LED on 81 01 33 01 01 FF LED off 81 01 33 01 00 FF ID Inquiry 81 09 04 22 FF Response 90 50 zz xx 00 yy FF z...

Page 231: ...uiry command Note that this inquiry can produce a reply up to 128 bytes long Focus Autofocus will automatically be disabled when it locks So you have to issue a new Autofocus on command each time you start a pan tilt zoom move For best results also issue an Autofocus on when you stop a move in case autofocus was locked while moving Presets Preset commands are currently not supported The camera wil...

Page 232: ...Switch The TANDBERG Video Switch TVS is a rack mountable hardware option for TANDBERG 6000 MXP and 3000 MXP codecs that delivers the ability to daisy chain multiple HD cameras and provides support for third party HD cameras This section of the Reference User Guide explains the TANDBERG Video Switch basics as well as how to set up different daisy chained solutions ...

Page 233: ...et left and right 1 Control cable 6 5m for Video Switch to Precision HD camera 1 HDMI cable 6 5m for Video Switch to precision HD camera 1 TRC4 TANDBERG Remote Control Please report any discrepancies immediately Cameras You may combine TANDBERG HD Precision cameras with analog sources equipped with component video outputs Just add them to the chain of cameras in the diagram shown overleaf but make...

Page 234: ...r TANDBERG Precision HD cameras RJ11 RJ45 RJ11 RJ45 RJ11 RJ45 DVI HDMI DB9 RJ45 RJ45 DB9 DB 9 RJ 45 DVI HDMI DVI HDMI Camera 2 Camera 3 Camera 4 Primary chain To upgrade the software of the Precision HD camera connect the cameradirectlytothemaincamerasocketoftheCodec thesocketthat otherwise is used when connecting the Video Switch to the Codec Power the units and the upgrade will start automatical...

Page 235: ...mes in addition to the one on previous page Audio out Data Net PC Card 1 Single 2 Single Videoout Video in 3 Dual 2 Aux 3 Doc 4 VCR VCR Ethernet PC DVI I in DVI I out 1 2 4 Audio in 1 Mic 1 2 Mic 2 3 USB USB DC in I O Camera Connect WAVE camera power supply here RJ11 RJ45 RJ11 RJ45 S video S video RCA RCA RCA RCA RJ45 DB9 RJ45 DB9 Camera 1 Camera 2 Camera 3 TANDBERG 6000MXP Codec TANDBERG 3000MXP ...

Page 236: ...nits may or may not be partly or fully controllable Connect Video Switch power supply as shown overleaf Control in Control in Audio out Data Net PC Card 1 Single 2 Single Videoout Video in 3 Dual 2 Aux 3 Doc 4 VCR VCR Ethernet PC DVI I in DVI I out 1 2 4 Audio in 1 Mic 1 2 Mic 2 3 USB USB DC in I O Camera Connect camera power supply here Camera 1 Camera 2 DB 9 Mini DIN RCA RCA RCA RCA Mini DIN Min...

Page 237: ...l also be possible when the switch is not connected xconfiguration Preset 1 15 SwitchVideoSource 0 6 Will switch the TANDBERG Video Switch to the given input when the preset is activated xconfiguration MainVideoSource DuoVideoSource 1 6 Will not be changed 1 will mean current input on the switch xconfiguration switch source 1 6 Specify which input source to use on the switch This will only cause a...

Page 238: ...chained to the switch will start with id 2 The codec will automatically recognize this and map the cameras accordingly VISCA Serial Ports The switch has a total of 4 serial ports that communi cate using the VISCA protocol Port 0 on the THSI interface is always connected to the codec Port 1 is the primary VISCA chain for cameras connected to the Switch Port 2 is the secondary VISCA chain for the ca...

Page 239: ... 01 40 20 3f are switch control commands Command Set Command Packet Comments SW_Input_Set 8x 01 40 20 0p ff Sets which input to use p 0 5 This will generate a SW_Input_Push on the THSI Visca port if issued from the dual visca port and vice versa Misc Command Command Packet Comments CAM_Boot 8x 01 42 ff Reboot the switch This will also reset se rial speed to 9600 Inquiries Messages starting with 8x...

Page 240: ...les or power cables during lightning storms Dust Do not operate the apparatus in areas with high concentration of dust Vibration Do not operate the apparatus in areas with vibration or place it on an unstable surface Power Connection and Hazardous Voltage The product may have hazardous voltage inside Never at tempt to open this product or any peripherals connected to the product where this action ...

Page 241: ...ject product is A Class ITE product and the following statement is clearly marked in the user manual and nameplate ໄ ᯢ ℸЎ A 㑻ѻકˈ ๗Ёˈ䆹ѻકৃ㛑Ӯ䗴៤᮴㒓 ᑆᡄDŽ 䖭 ᚙ މ ϟˈৃ㛑䳔㽕 ᇍ ᑆᡄ䞛পߛᅲৃ㸠ⱘ ᮑDŽ WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures ໄᯢ᠔ ԡ㕂 Position of the Declaration ৌ Company Name TANDBERG...

Page 242: ...Philip Pedersens vei 22 1366 Lysaker Norway Telephone 47 67 125 125 Fax 47 67 125 234 Video 47 67 117 777 E mail tandberg tandberg com ...