![TANDBERG Codec 3000 MXP Reference Manual Download Page 208](http://html.mh-extra.com/html/tandberg/codec-3000-mxp/codec-3000-mxp_reference-manual_816769208.webp)
208
TANDBERG 3000
MXP
&
6000
MXP
REFERENCE GUIDE FOR SYSTEM INTEGRATORS
Status Information – xstatus /xstatus.xml
D 13887.08
MAY 2008
Status information followed by a
*
will not be shown unless Detailed Level has been set to 2
–
see
XACLI – Special commands – xpreferences
Switch
(connected =
True / False
):
Input:
Format:
Sync:
Sync 1:
Sync 2:
Sync 3:
Sync 4:
Example:
*s Switch (connected=True):
Input: 1
Format: 1280X720p60
Sync: True
Sync 1: True
Sync 2: True
Sync 3: False
Sync 4: False
*s/end
INFO:
xstatus switch will give information about sync status for the active input, the format, and sync status for all DVI-D inputs. Active input may differ from what is given in the xconfiguration Switch Source
setting. This is because an external control system may also change the input. Information about software version and ID will be given by xstatus camera 1.
Switch