![TANDBERG Codec 3000 MXP Reference Manual Download Page 83](http://html.mh-extra.com/html/tandberg/codec-3000-mxp/codec-3000-mxp_reference-manual_816769083.webp)
83
TANDBERG 3000
MXP
&
6000
MXP
REFERENCE GUIDE FOR SYSTEM INTEGRATORS
Configuration-type Commands – xconfiguration / configuration.xml
D 13887.08
MAY 2008
H323Gatekeeper
Authentication
Password: <S: 0, 49>
Please see above.
NOTE!
The password will not be listed when polling.
Example:
xconfiguration h323gatekeeper authentication password: xxx
H323Prefix: <S: 0, 4>
When dialling a number prefixed with digits specified by H.323 Prefix, and with Net: Auto, an H.323 call will be placed.
Example:
xconfiguration h323prefix: 5
HTTP
Mode: <On/Off>
Enables/disables HTTP.
Example:
xconfiguration http mode: on
HTTPS
Mode: <On/Off>
Enables/disables HTTPS.
Example:
xconfiguration https mode: on
HTTPS
VerifyServerCertificate: <On/Off>
TANDBERG MXP systems now support secure management when communicating with the TMS. For more information see the TANDBERG White Paper “Implementing
Secure Management” which describes how to configure secure HTTPS between TANDBERG products. To find the document, follow the link: http://www.tandberg.com/support/
documentation.php and select White Papers.
Example:
xconfiguration https verifyservercertificate: on
IdReport
H323: <H323Id/E164Alias/IPAddress>
Selects what identifier to present as remote number for incoming H.323 calls.
Example:
xconfiguration idreport h323: h323id
H323Gatekeeper
cont...
— IdReport