Pag. 56
Maintenance and use manual
COMBUSTION ROTOR 2018 Ver. 1.1 from 24/06/18
11.
Troubleshooting and possible immediate interventions
PROBLEM
CAUSE
SOLUTIONS
The oven does
not get hot or it is
slowly heated
Main switch
Make sure that the on/off switch and the residual
current device is placed upstream of the oven,
they are properly plugged in and the power sup
-
ply cables are connected to the oven
Main protection fuses inter-
rupted
Check the main protection fuse continuity and if
faulty, replace
One or more transformer
protection fuses inter-
rupted.
Check cause and replace blown fuses (reset
tripped circuit breaker or replace if faulty)
One or more circuit break-
ers in incorrect position.
Check if the circuit breakers are in operational posi-
tion: in not, set them in the "I" position.
Power supply unit is not
working
Check connection and power supply cables, and
replace the cable or replace the card if needed.
Control unit fuse inter-
rupted
Replace it
Control unit set to pro-
grammed start-up
Make sure the chamber controller is adjusted
to "ON" position and programmed start-up si
disabled
Alarm signals displayed in
the control unit
see alarm instructions § 13.8
Safety thermostat discon-
nected;
Check if the safety thermostat has been tampered
with (pos. 2 §12.1 ) and, if that is the case, reset it by
pressing the red button under the hole on the box .
Door limit switch not en
-
gaged.
Check the door's limit switch found in the lower
right corner. When the door closes the limit switch
is squeezed. If faulty, replace.
Burner operation , fuel,
chimney
Ensure the smooth operation of the burner, which
should ignite when the temperature drops below
the set point and disable when the set point is
reached.
Ensure the fuel's smooth flow to the burner.
Check if the chimney is blocked by soot or other
obstructions and if it has cracks or breaks capable
of compromise the draft.
Electrical connections inter-
ruption
Check electrical connection continuity
Summary of Contents for ROTOR RT 68
Page 1: ...Cod ZM 005202_18_1 COMBUSTION VERSION Ver 1 1 from 24 06 2018...
Page 7: ...Pag 7 1 2 Declaration CE of conformity...
Page 28: ...Pag 28 Maintenance and use manual COMBUSTION ROTOR 2018 Ver 1 1 from 24 06 18...
Page 62: ...Pag 62 Maintenance and use manual COMBUSTION ROTOR 2018 Ver 1 1 from 24 06 18...
Page 63: ...Pag 63 PLATFORM ASSEMBLY PARTICULARITIES...
Page 65: ...Pag 65...
Page 66: ...Pag 66 Maintenance and use manual COMBUSTION ROTOR 2018 Ver 1 1 from 24 06 18...
Page 67: ...Pag 67...
Page 71: ...Pag 71 103 104...
Page 81: ...Pag 81...
Page 82: ...Pag 82 Maintenance and use manual COMBUSTION ROTOR 2018 Ver 1 1 from 24 06 18 13 Control Panel...
Page 101: ...Pag 101...
Page 109: ...Pag 109...
Page 111: ...Pag 111...
Page 113: ...Pag 113...
Page 115: ...Pag 115...
Page 116: ...Pag 116 Maintenance and use manual COMBUSTION ROTOR 2018 Ver 1 1 from 24 06 18...
Page 117: ...Pag 117...
Page 118: ...Pag 118 Maintenance and use manual COMBUSTION ROTOR 2018 Ver 1 1 from 24 06 18...
Page 119: ...Pag 119...
Page 120: ...Pag 120 Maintenance and use manual COMBUSTION ROTOR 2018 Ver 1 1 from 24 06 18...
Page 121: ...Pag 121...
Page 124: ...Pag 124 Maintenance and use manual COMBUSTION ROTOR 2018 Ver 1 1 from 24 06 18...