Troubleshooting with Error Messages
Use the information in Table L to troubleshoot the system based
on the condition description (conddescr) parameter in a message.
Note:
If only the character “C” is displayed on the terminal every
few seconds, the TimeSource 3600 system has restarted with cor-
rupt software. Download and install the system software again,
using the procedure in the Software Release Document that came
with the software.
Table L. Message Troubleshooting
Message
Meaning
Action
CRITICAL ALARMS
HARDWARE FAULT
A failure has been detected on
the shelf hardware.
Replace the plug-in card.
MAJOR ALARMS
HOLDOVER
All inputs (GPS signal and span
inputs) are lost or
unacceptable, and the system
is now using the internal
oscillator.
Troubleshoot the GPS and SPAN x error
messages.
Check cable, source, etc.
MINOR ALARMS
BATTERY x FAIL
The specified
–
48 V battery
input has failed.
Troubleshoot, and repair, the specified
–
48 V battery input.
BT3 WARMUP
The system is in a power-up
state when it should not be.
Perform the same action as shown in
GPS ERROR message.
Summary of Contents for TimeSource 3600
Page 1: ...TimeSource 3600 GPS Primary Reference Source 097 72060 01 Issue 2 ...
Page 4: ...4 TimeSource 3600 This page intentionally left blank ...
Page 16: ...16 TimeSource 3600 This page intentionally left blank ...
Page 121: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Page 223: ...6 Chapter Specifications This chapter provides equipment specifications ...
Page 247: ...Index ...