Retrieve Performance Monitoring (cont’d)
Note:
PHASE 1M Data types:
•
The TimeSource 3600 collects a full 7 days of 1 minute
phase data.
•
The 1 minute phase data is displayed in 1 hour groups.
Each request for 1 minute phase is synchronized to the
hour.
•
Any mondat/montm combination outside of the past 7 day
window is denied. Any time increment may be entered. The
system rounds the value to the nearest hour, i.e., the
minute and second field of the montm is ignored.
•
The first value (monval) is the oldest value in the range
selected. For example, if montm = 8:45:32, the first monval
will exceed time 8:00:00 followed by the value at 8:01:00,
etc.
•
Entering the date or time is optional. Type a semicolon
after montype to display the most recent statistics for the
specified montype.