Edit Communication
This command changes communication port parameters. The
command format is:
ED-COM:[<tid>]:<aid>:<ctag>:::<spec_block>;
Notes:
1. Ethernet ports 5001, 5002, 5003, and 5004 are set up to act as
serial communication ports, so that a terminal program on a
computer connected to these ports can communicate
effectively.
2. Ethernet port 5551 is set up to allow an element manager to
connect with it for TL1 commands and responses. TL1
autonomous messages are sent through port 5550, which
connects to an element manager to send one or a group of
autonomous messages, then disconnects. Port 5550 is not to be
reconfigured.
Aid
Value
Item Addressed
COM-a
a = 1
Serial communication por t 1 (COM1)
a = 2
Serial communication por t 2 (COM2)
a = 3
Serial communication por t 3 (Craft)
a = 5001
Ethernet user interface por t 5001 (Note 1)
a = 5002
Ethernet user interface por t 5002 (Note 1)
a = 5003
Ethernet user interface por t 5003 (Note 1)
a = 5004
Ethernet user interface por t 5004 (Note 1)
a = 5551
Ethernet element manager interface por t 5551 (Note 2)
Summary of Contents for TimeSource 3600
Page 1: ...TimeSource 3600 GPS Primary Reference Source 097 72060 01 Issue 2 ...
Page 4: ...4 TimeSource 3600 This page intentionally left blank ...
Page 16: ...16 TimeSource 3600 This page intentionally left blank ...
Page 121: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Page 223: ...6 Chapter Specifications This chapter provides equipment specifications ...
Page 247: ...Index ...