Use the Edit Communications command to set the communications parameters of
port 5551. An Element Manager connects to port 5551 for TL1 command and
response messages. The following values for port 5551 are set at the factory and
appear at reset:
MONMSG=INH (monitors only the current port for messages)
KEEPALIVE=0 (does not send a COMPLD message to keep connection open)
ENDOFTEXT=0 (does not include an end-of-text code with a TL1 message)
ECHO=INH (does not echo characters received)
COMPRI=ALW1 (normal communication, including autonomous messages)
AUTOLOGOFF=0 (does not log off the user during inactivity)
SWCONTROL=INH (uses no flow control)
If these values require change, use the Edit Communications command to set
communications parameters for TL1 communications.
ED-COM::COM-5551:<ctag>:::[MONMSG=b[,]][KEEPALIVE=c[,]]
[ENDOFTEXT=d[,]][ECHO=b[,]][COMPRI=e[,]][AUTOLOGOFF=c[,]
][SWCONTROL=b];
MONMSG=b
= Monitors messages on all ports (b = ALW), or current port
(b = INH)
KEEPALIVE=c
= Inactive minutes until the unit sends a COMPLD message to
keep the connection from being closed (c = 0 to 255)
ENDOFTEXT=d = Hex code added to responses before semicolon (d = 0
(disabled) to 9F)
ECHO=b
= Echoes characters received so they appear on the user’s
screen as typed (b = ALW), or inhibits echo (b = INH)
COMPRI=e
= Sets the communication port capabilities as follows:
ALW0 = normal communication, no autonomous messages
ALW1 = normal communication, autonomous messages
ALW2 = autonomous messages received, logged on or not
INH = closes connection and keeps port from use
(command must go to another port) (if the port is in use, this
command also logs off the user)
AUTOLOGOFF=c = Inactive minutes until the unit logs off the user, keeping the
connection open (c = 0 to 255)
SWCONTROL=b = uses software (XON/XOFF) flow control (b = ALW), or
no flow control (b = INH)
Procedure G. Power Up (cont’d)
Step
Procedure
Summary of Contents for TimeSource 3600
Page 1: ...TimeSource 3600 GPS Primary Reference Source 097 72060 01 Issue 2 ...
Page 4: ...4 TimeSource 3600 This page intentionally left blank ...
Page 16: ...16 TimeSource 3600 This page intentionally left blank ...
Page 121: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Page 223: ...6 Chapter Specifications This chapter provides equipment specifications ...
Page 247: ...Index ...